Loading...
Item 8 - PlansINDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A OOC 8/13/2020 OFFSET DECREASE, SETBACKS, CORRECTIONS **** **** **** **** LICENSE GENERAL NOTES (E) DRIVEWAY 0 30'60' Scale:1" = 30'-0' PROPERTY PLAN Front Of House (E) DRIVEWAY 3' F S B 1 2 " S e t b a c k 3' F S B 3' F S B 3' F S B 3' F S B 3' F S B 1 2 " S e t b a c k 1'- 6 " F S B 1'-6 " F S B 1'- 6 " F S B 1'- 6 " F S B 1 ' - 6 " F S B 3' FSB 1 2 " F S B 3' F S B SV SV SV SV SV 1 ' - 6 " F S B 1 ' - 6 " F S B 1'- 6 " F S B 1 2 " S e t b a c k 1'-6" F S B 1'- 6 " F S B 12" Se t b a c k 1'- 6 " F S B 1'-6" S e t b a c k 1'-6" F S B P i t c h 6 / 1 2 M P 1 P i t c h 6 / 1 2 M P 2 P i t c h 6 / 1 2 M P 3 P i t c h 6 / 1 2 M P 4 P i t c h 6 / 1 2 M P 8 Scale:1/16" = 1' SITE PLAN 01'32'16' LEGEND MP3 24 68 24 68 Comp Shingle 2 Stories MP2 24 68 24 68 Comp Shingle 2 Stories MP1 23 338 23 338 Comp Shingle 2 Stories MP4 24 68 24 68 Comp Shingle 2 Stories MP8 24 68 24 68 Comp Shingle 2 Stories #SSTAMPTX #ESTAMPTX NTS TYPICAL PV SIDE VIEWSV Scale: 1 1/2" = 1' STANDOFFS1 #SSTAMPTX #SSTAMPTX MODULE SPECS INV 1 INVERTER SPECS 3 LICENSEGENERAL NOTESMAIN PANEL SPECSGROUND SPECS AC Y 7 GNDGND X 5 N EGC L2 L14 W N EGC L2 L14 W N EGC L2 L14 W 6 L1NEGCL2 POI Z Y X W 6 4 5 7 Z L2 L1 N EGC/ GEC GND N 240V Inverter 1 IND EGC DC- DC+ DC- DC+ DC- DC+ EGC DC- DC+ EGC DC- DC+ MP 1: 1x6 MP 3/8: 1x12 1 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC2Vmp= VAC Imp= AAC 3 GD PV #ESTAMPTX LICENSEGENERAL NOTESMAIN PANEL SPECSGROUND SPECS AC U 16 GNDGND T 14 N EGC L2 L113 S N EGC L2 L113 S N EGC L2 L113 S 15 L1NEGCL2 POI V U T S 15 13 14 16 V MODULE SPECSINVERTER SPECS INV 2 L2 L1 N EGC/ GEC GND N 240V Inverter 2 IND EGC DC- DC+ DC- DC+ DC- DC+ A DC- DC+ EGC DC- DC+ EGC DC- DC+ MP 1: 1x6 MP 2/4: 1x6 MP 2: 1x7 A 8 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC8 9 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC9 10 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC10 11 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC11 12 Vmp = VAC Imp = AAC 12 GD PV #ESTAMPTX CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 1500 Bent Creek Dr OPERATING VOLTAGE = 240V JB-7604273-00 - Address: 1500 Bent Creek Dr OPERATING VOLTAGE = 240V JB-7604273-00 - Address: 1500 Bent Creek Dr OPERATING VOLTAGE = 240V JB-7604273-00 - Address: 1500 Bent Creek Dr OPERATING VOLTAGE = 240V JB-7604273-00 - Address: 1500 Bent Creek Dr OPERATING VOLTAGE = 240V JB-7604273-00 LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set LB-040137-10X Per Code: NEC 408.4 Label Location: (BLC) LB-040144-10X Per Code: NEC 220 Label Location: (BLC) LB-200025-10X Per Code: NEC 312.8.A(3) Label Location: (MP) LB-030142-10X Per Code: NEC 705.12(B)(3) Label Location: (MP) LB-040141-10X Per Code: Label Location: (MP) LB-040139-10X Per Code: Label Location: (MP) LB-040140-10X Per Code: Label Location: (MP) LB-040138-10X Per Code: Label Location: (MP) LB-200011-10X Per Code: NEC 705.12(B)(3) Label Location: (MP) LB_200127_10X Per Code: NEC 705.12.B.2.3.c Label Location: (MP) LB-200110-10X Per Code: Per 706.7(D) label to be marked in field Label Location: (MP) (MP): Main Panel (BLC): Backup Load Center (AC): AC Disconnect Label Set TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous2 5 kW (charge and discharge) Real Power, peak (10 s, off-grid/backup)2 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,3 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions1 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight1 114 kg (251.3 lbs) Mounting options Floor or wall mount 1 Dimensions and weight differ slightly if manufactured before March 2019. 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 In Backup mode, grid charge power is limited to 3.3 kW. 3 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 753 mm (29.6 in) 147 mm (5.75 in) 1150 mm (45.3 in) Contact Tesla for additional information. TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Main panelSub panel Solar Home loads Solar inverter Utility meter GridBackup Gateway Powerwall Backup loads Optional NA - BACKUP - 2019-06-11 Utility meter Grid Backup Gateway including service disconnect Main panel Solar Whole home backup Solar inverter Powerwall Optional Solar Inverter for North America Single Phase Solar Inverter for North America M4-TL-US | M5-TL-US | M6-TL-US | M8-TL-US | M10-TL-US | M10-4-TL-US Key Features: x Smart inverter with BLE, optional WiFi, Ethernet, 3G / 4G cellular communication x Optional revenue grade meter (compliant with ANSI C12.20, Class 0.5) x Support bi-directional cloud communication x Support remote diagnosis and OTA x Type 4 protection x Built-in AFCI & Rapid shutdown controller x CEC efficiency 97.5% x UL 1741 SA, HECO compliant x CA Rule 21 Phase 1 & 2 & 3 compliant Solar Inverter for North America Rev 14 - 02/2020 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US INPUT (DC) Max. system voltage 600 V Nominal voltage 380 V Max. operating voltage 540 V Operating MPPT voltage range 50 V to 480 V Max. input current per MPPT 12 A 12 A 12 A 12 A 20 A 10 A Max. short circuit current per MPPT 15 A 15 A 15 A 15 A 30 A 15 A Max. DC/AC ratio 1.3 DC disconnect Integrated MPP tracker 2 2 3 3 2 4 Input strings available 2 - 2 2 - 2 2 - 2 - 2 2 - 2 - 2 2 - 2 2 - 2 - 2 - 2 OUTPUT (AC)  Nominal output power @ 240Vac 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W Max. output power @ 240Vac 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W Nominal output power @ 208Vac 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W Max. output power @ 208Vac 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max. continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating frequency 60 Hz Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption < 1.5 W 1) THD @ nominal power < 3 % Power factor @ nominal power > 0.99 Adjustable power factor range 0.85i to 0.85c GENERAL SPECIFICATION Max. efficiency 98% CEC efficiency 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V Operating temperature range -22 °F to 149 °F (-30 °C to 65 °C) with derating above 113 °F (45 °C) Storage temperature range -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Max. operating altitude 9,843 ft (3,000 m) Acoustic noise < 45 dB(A) @ 3 ft (1m) Solar Inverter for North America Rev 14 - 02/2020 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US MECHANICAL DESIGN Dimensions (W x H x D) 16.7 x 23.2 x 5.9 in (425 x 590 x 150 mm) Display LED indicators Weight 2) 41.9 lbs (19.0 kg) 41.9 lbs (19.0 kg) 44.3 lbs (20.1 kg) 45.2 lbs (20.5 kg) 47.6 lbs (21.6 kg) 47.6 lbs (21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Rapid Shutdown Initiation Method Loss of AC or DC Disconnect Communication interface BLE, optional WiFi, Ethernet, 3G / 4G cellular communication Enclosure material Die-casting aluminum STANDARDS Enclosure protection rating Type 4 Safety UL 1741, CSA-C22.2 No. 107.1-01 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547, IEEE 1547.1 EMC FCC part 15 Class B AFCI UL 1699B (Type 1), NEC 2017 Article 690.11 Rapid shutdown protection NEC 2017 690.12 3) Integrated meter ANSI C12.20, Class 0.5 Grid support regulation UL 1741 SA, California Rule 21 phase 1 & 2 & 3, HECO Compliant WARRANTY Standard warranty 10 years 1) Without consumption of communication card 2) Without weight of revenue grade meter 3) Compliant with Tigo rapid shutdown system or APS rapid shutdown system Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 6am to 6pm PST (apart from Holidays) www.Delta-Americas.com Residential Energy Storage Solution for North America Rev 05 – 09/2019 © Copyright 2018 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Accessory: MCI (Middle Circuit Interrupter) Features: z Automatic function test upon startup, ensure safety z Enclosure protection Type 4 z Meet 2017 NEC Article 690.12 Rapid Shutdown z No installation needed for every PV Module, make better cost performance for PV system z With PLC, no additional cable needed INPUT RATINGS  Delta part number GPI00010110 GPI00010114 Maximum system voltage 600 Vdc Rated input operating voltage 6 Vdc to 80 Vdc Number of input circuit 1 Startup voltage 22 V Rated input current 12 A OUTPUT RATINGS  Rated output current 12 A Control signal method PLC signal GENERAL DATA  Dimensions (W x H x D) 4.6 x 6.5 x 3.0 in (117 x 165 x 76.5 mm) (without cable) 3.8 x 6.5 x 1.1 in (97.3 x 165 x 27.3 mm) (without cable) Weight 2.0 lbs (0.9 kg) 1.4 lbs (0.64 kg) Bracket Groove adapter bracket Without Cooling Natural convection DC input / output connectors MC4 PV connector Cable length with connector Input : 5.9 in (150 mm) Output: 47.2 in(1200 mm) Input : 5.9 in (150 mm) Output : 12 in (305 mm) Enclosure material Plastic Operating temperature -40 °F to 185 °F (-40 °C to 85 °C) Storage temperature -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) above sea level Self power consumption <3.0 W Warranty 10 years STANDARD COMPLIANCE  Enclosure protection rating Type 4 / IP67 Safety UL 1741, CSA C22.2 No. 330-17 Rapid shutdown NEC 2017 Article 690.12 EMC FCC Part 15 Class B TESLA.COM/ENERGY Backup Gateway 2 POWERWALL 660 411 149 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240V Feed-In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA1 Overcurrent Protection Device 100-200A; Service Entrance Rated1 Overvoltage Category Category IV AC Meter Revenue accurate (+/– 0.2 %) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control, backup, and off-grid Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years COMPLIANCE INFORMATION Certifications UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 NA 2020-05-23 1 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-flush mount YIELD SECURITY ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.QTM) ANTI LID TECHNOLOGY (ALT) Product and Performance Warranty Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. ZEP COMPATIBLETM FRAME DESIGN High-tech black Zep CompatibleTM frame, for improved aesthetics, easy installation and increased safety. A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and industrial buildings Q.PEAK DUO BLK-G6+ / SC 330-345 ENDURING HIGH PERFORMANCE Į [% / K] + 0.04 ȕ [% / K] − 0.27 Ȗ [% / K] − 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) 330 335 340 345 [W] 330 335 340 345 [A] 10.41 10.47 10.52 10.58 [V] 40.15 40.41 40.66 40.92 [A] 9.91 9.97 10.02 10.07 [V] 33.29 33.62 33.94 34.25 [%] ≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W] 247.0 250.7 254.5 258.2 [A] 8.39 8.43 8.48 8.52 [V] 37.86 38.10 38.34 38.59 [A] 7.80 7.84 7.89 7.93 [V] 31.66 31.97 32.27 32.57 [V] 1000 (IEC) / 1000 (UL)II [A DC] 20 C (IEC) / TYPE 2 (UL) [lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa) − 40 °F up to + 185 °F (− 40 °C up to + 85 °C)[lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa) 3 See Installation Manual Certified UL 1703 (254141) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Format 68.5 × 40.6 × 1.57 in (including frame) (1740 × 1030 × 40 mm) Weight 47.4 lbs (21.5 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q C E L L S Q. P E A K D U O B L K - G 6 + / S C _ 3 3 0 - 3 4 5 _ 2 0 1 9 - 1 1 _ R e v 0 1 _ N A ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1 Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Normal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS Protection Class Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703 Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull (UL)3 QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016, Application Class II, U.S. Patent No. 9,893,215 (solar cells) 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] 100 95 90 85 80 75 1552520010 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 37.4" (950 mm) 68.5" (1740 mm) 4 × Fastening points (DETAIL A) Frame 6.06" (154 mm) 40.55" (1030 mm) 38.6" (981 mm) 1.57" (40 mm) 8 × Drainage opening 0.14" × 3.1" (3.6 mm × 8 mm) 6 × Grounding points ø 0.16" (4 mm) Label DETAIL A 0,472" (12 mm) 0.354" (9 mm)1.063" (27 mm) 15.6“ (395 mm) 7.09" (180 mm) 4 × Drainage opening ≥ 43.3" (11 00 m m) ≥ 43. 3" (11 00 m m) DC- DC+ 1 GD · · · · · DC1 HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU ¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\ UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP IRUFRPSRVLWLRQVKLQJOHURRIV DQ\PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ 6SHFL¿FDWLRQV HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\ UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP 1H[W/HYHO390RXQWLQJ7HFKQRORJ\ ]HSVRODUFRP 3DUW1R /LVWHGWR8/ &DSWXUHG:DVKHU/DJ 3DUW1R       )ODVKLQJ,QVHUW 3DUW1R /LVWHGWR8/ $UUD\6NLUW 3DUW1RRU /LVWHGWR8/ 3DUW1RRU /LVWHGWR8/ (QG&DS 3DUW1R / RU 5 RU '&:LUH&OLS 3DUW1R /LVWHGWR8/ *URXQG=HS9 3DUW1R /LVWHGWR8/DQG8/ ,QWHUORFN 3DUW1RRU /LVWHGWR8/ /HYHOLQJ)RRW 3DUW1R /LVWHGWR8/ ZS COMP DATASHEET 2 DESCRIPTION PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond ZS Span has a UL 1703 Class “A” Fire Rating when installed using modules from any PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ ROOFING SYSTEM SPECIFICATIONS SPECIFICATIONS Designed for pitched roofs Installs in portrait and landscape orientations =6&RPSVXSSRUWVPRGXOHZLQGXSOLIWDQGVQRZORDGSUHVVXUHVWRSVISHU8/ Engineered for compliance with ASCE 7-16 wind load requirements =6&RPSJURXQGLQJSURGXFWVDUH8/OLVWHGWR8/DQG8/ =6&RPSERQGLQJSURGXFWVDUH8/OLVWHGWR8/ (QJLQHHUHGIRUVSDQVXSWR´DQGFDQWLOHYHUVXSWR´ =HSZLUHPDQDJHPHQWSURGXFWVOLVWHGWR8/IRUZLUHSRVLWLRQLQJGHYLFHV ZS COMP DATASHEET 3 SKIRT GRIP END CAP INTERLOCK GROUND ZEP V2 LEVELING FOOT CAPTURED WASHER LAG FLASHING INSERT /LVWHGWR8/DQG8/ Part #850-1511 /LVWHGWR8/ Part #850-1397 /LVWHGWR8/ Part #850-1613 or #850-1388 ARRAY SKIRT /LVWHGWR8/ Part #850-1608 or #500-0113 /LVWHGWR8/DQG8/IRU:LQG'ULYHQ5DLQ 3DUW MOUNTING BLOCK /LVWHGWR8/ 3DUWRU /LVWHGWR8/ Part #850-1633 3DUWRU /HIW 3DUWRU 5LJKW 3DUWDQG DC WIRE CLIP Listed to UL 1565 Part #850-1509 PVRSA Model: ZS Rapid Shutdown Array (Applicable to ZS Comp, ZS Span, ZS Ramp, and ZS Seam) Category QIJR, Report Date: 2020-05-01 TABLE OF ESSENTIAL ELEMENTS Function Manufacturer Model No. Firmware Versions and Checksums &HUWL¿FDWLRQ6WDQGDUG PVRSE Mid Circuit Interrupter (MCI)Delta Electronics GPI00010110 2 2.1.6 UL 1741 PVRSE Inverter Delta Electronics M4, M5, M6, M8, M10 Sys: 2.2.11 Pwr: 1.4.9 Safety: 1.4.3 UL 1741 PV Module Hanwha Q-CELLS Q.PEAK DUO BLK-G5/SC315 Q.PEAK DUO BLK-G5/SC320 N/A UL 1703 Interlock Tesla ZEP 850-1613-001 ZEP 850-1388-001 ZEP 850-1281-001 N/A UL 2703 Ground Zep Tesla ZEP 850-1511-001 ZEP 850-1172-002 N/A UL 467 UL 2703 DC Wire Clip Tesla ZEP 850-1509-001 ZEP 850-1448-001 N/A UL 1565 Homerun Wire Clip Tesla ZEP 850-1510-001 N/A UL 1565 PVRSA Initiator 1 (See installation req. below) 1RQ6SHFL¿F N/A N/A N/A 1 Dedicated PV system AC circuit breaker or AC disconnect switch, labeled per NEC 690.12 requirements. 2 Applies to variations of this part number, e.g. suffixes. Note: PVRSA installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements. PVRSA INSTALLATION REQUIREMENTS Max System Voltage 600 Vඌඋ Max Array Internal Voltage After Actuation 165 Vඌඋ (cold weather open circuit) Max Series-Connected Panels between MCI Output Connections: 3 Max Series-Connected Panels Connected to MCI Inputs: 1 OTHER INSTALLATION INSTRUCTIONS 1. MCIs shall be mounted to module frames with Delta-supplied brackets. 2. An MCI must be connected to one end of each series string or sub-array string. 9HUL¿FDWLRQWKDW0&,VDUHLQVWDOOHGZLWKRUIHZHUPRGXOHVEHWZHHQ0&,RXWSXWFRQQHFWLRQVVKDOOEHGRFXPHQWHGIRULQVSHFWLRQE\YROWDJH measurement logs and/or as-built string layout diagrams. 4. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA initiator and shall be sized and installed LQDFFRUGDQFHZLWK1(&UHTXLUHPHQWV7KHVSHFL¿FSDUWVKDOOEHLGHQWL¿HGRQWKHDVEXLOWV\VWHPGUDZLQJV &HUWL¿FDWLRQ0DUNRI8/RQWKHLQVWDOODWLRQLQVWUXFWLRQVLVWKHRQO\PHWKRGSURYLGHGE\8/WRLGHQWLI\SURGXFWVPDQXIDFWXUHGXQGHULWV &HUWL¿FDWLRQDQG)ROORZ8S6HUYLFH7KH&HUWL¿FDWLRQ0DUNIRUWKHVHSURGXFWVLQFOXGHVWKH8/V\PEROWKHZRUGV&(57,),('DQG 6$)(7<WKHJHRJUDSKLFLGHQWL¿HU V DQGD¿OHQXPEHU