2003 International Residential Code
ORDINANCE NO. 874
OFFICIAL RECORD
AN ORDINANCE ADOPTI~G THE 2003 EDITION OF THE INTERNATIONAL RESIDENTIAL
CODE FOR ONE- AND TWO-FAMILY DWELLINGS, REGULATING THE ERECTION,
CONSTRUCTION, ENLARGEMENT, ALTERATION, REPAIR, MOVING, REMOVAL,
DE"10LITION, CONVERSION, OCCUPANCY, EQUIPMENT, USE, HEIGHT, AREA AND
\IAINTENANCE OF ALL ONE- AND TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE-
FAMILY DWELLINGS (TOWNHOUSES) I~ THE CITY OF SOUTHLAKE AND PROVIDING FOR
rHE ADOPTION OF LOCAL AMENDMENTS THERETO; PROVIDING FOR_RECORDING OF
"¡CCH CODE AS A PVBLIC RECORD PROVIDING THAT THIS ORDINANCE SHALL BE
CUMlJLATIVE OF ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING
FOR A PENALTY FOR VIOLATIONS HEREOF; PROVmING A SAVINGS CLAUSE; PROVIDING
FOR PllBLICATION IN PAMPHLET FORM; PROVIDING FOR PCBLICATION IN THE OFFICIAL
\fEWSP APER; AND PROVIDING AN EFFECTIVE DATE.
WHEREAS, the City of Southlake IS a home rule city acting under its charter adopted by the electorate pursuant
to Artlck XL Section '\ of the Texas Constitution and Chapter 9 of the Local Govemment Code; and
WHEREAS, the City Council of the City of Southlake deems it necessary to adopt this ordinance providing
1111l11mUill standards to safeguard the health, property, and welfare of the citizens of Southlake by regulating and
controllll1g the use, occupancy, maintenance, repair, design, construction and quality of materials for residential buildings
and structures within the City.
WHEREAS, beginning in the summer of2003, NCTCOG's Regional Codes Coordinating
Committee (RCCC) and its four advisory boards conducted 26 open review meetings over a 10-
month period to review the 2003 editions of the International Codes and to develop regional
amendments. Their review and recommendations were completed and endorsed by NCTCOG's
Executive Board in March 2004. Now NCTCOG encourages jurisdictions in North Central Texas to
adopt the 2003 International Rcs[(lcntial Codcfor Onc- and nvo-FamiZv Dwellings along with its
respective regional amendments with an effective date of July 1,2004:
NOW, THEREFORE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
sm 'THLAKE, TEXAS:
SECTION 1
That the International ResidentIal Code for One- and Two-Family Dwellings, 2003 Edition, published by the
Internatinnal Code Council, including the standards referenced therein. including Appendix Chapters A, B, C, E, G, Hand
.I arc hereby adopted as the Residential Building Code of the City of Southlake regulating the erection, construction,
enlargement. alteration. repair. moving, removal, demolition, conversion, occupancy, equipment, use, height, area and
lllall1teml11ce of all one- and two-family dwellings, multiple single-family dwellings (townhouses) and their accessory
structures in the City of Southlake. True and correct copies of these documents are attached as Exhibit "A."
SECTION 2
That the 2003 International Residential Code, as adopted herein, is hereby amended as provided)n Exhibit "B"
incnrporated herein and attached hereto for all purposes of this ordinance. The City of Southlake, Texas may from time to
time determine that additional local modifications to the Building Code are necessary and approprIate to meet the ul1lque
needs of the City of Southlake, Texas. To effectuate these local modifications, the City Council shall enact individual
ordlllatll"es amending this Ordinance, tìIlly setting forth the change to be made in the Residential Building Code. Upon
adoption. copies of these amendments shall be attached to Exhibit "B" to this Ordinance.
SECTION 3
fhe materIal contained III Exhibit "A" to this ordinance shall not be included in theJormal municipal codification of
ordinances, but shall be maintained as a public record in the office of the City Building Official and will be available for
public lI1spection and copying during regular business hours
SECTION 4
fhis ordinance shall be cumulative of all provisions of ordinances of the City of Southlake, Texas, except where the
provisIons of this ordinance are in direct conf1ict with the provisions of such ordinances, in which event the conf1icting
prO\lslons of such ordinances are hereby repealed.
SECTION 5
It is hereby declared to be the intention of the City Council that the phrases, clauses, sentences, paragraphs, and
sectIOns of this ordinance are, severable, and if any phrase, clause sentence, paragraph or section of this ordinance shall be
dec lared unconstitutional by the valid judgment or decree of any court of competent jurisdiction, such unconstitutionality
shall not affect any of the remaining phrases, clauses, sentences, paragraphs and sections of this ordinance, since the same
would have been enacted by the City Council without the incorporation in this ordinance of any such unconstitutional
phrase, clause, sentence, paragraph or section.
SECTION 6
Any person, firm or corporation who violates, disobeys, omits. neglects or refuses to comply with or who resists
the enforcement of any of the provisions of this ordinance shall be fined not more than Two Thousand Dollars ($
2.0OCLOO) for all violations involving zoning, fire safety or public health and sanitation, including dumping or refuse, and
shall bc fined not more than five hundred dollars ($500) for all other violations of this ordinance each day that a violation
IS permItted to exist shall constitute a separate offense.
SECTION 7
All rights and remedies of the City of Southlake are expressly saved as to any and all violations ofthe provisions
of any ordinances affecting the regulation and control of the use, occupancy, maintenance, repair, design, construction and
quality oi'materials for buildings and structures within the City which have accrued at the time of the effective date of this
ordlllance; and, as to such accrued violations and all pending litigation, both civil and criminal, whether pending in court
or not. under such ordinances, same shall not be affected by this ordinance but may be prosecuted until final disposition
by the lourts.
SECTION 8
fhe City Secretary of the City of Southlake is hereby authorized to publish this ordinance in book or pamphlet
jorlll 1'01 general distribution among the public, and the operative provisions of this ordinance as so published shall be
admissIble in evidence in all courts without further proof than the production thereof.
SECTION 9
The City Secretary of the City of Southlake is hereby directed to publish in the official newspaper of the City of
South]ake, the caption, penalty clause, publication clause and_effective date of this ordinance one time within ten days
after passage of this ordinance, as requIred by Section 3.13 of the Charter of the City of Southlake.
SECTION 10
This ordinance sha1l be in fu1l force and effect from and after its passage and publication as required by law, but
not sonner than September 30 2004.
PASSED ANDAte' I I I h. IRST READING THIS OthDAY OF 11,4 ,2004.
,,,,wu,,,,,,•
pUTH.[�i ., vvv
o ...... .......14;
AS
ATTEST: (?.t/�` CITI(" RE S i
ti
PASSED AND APP'OVED ON SECOND READING' IISD.gra ��F� .� (D/ ,2004.
**Ao`'j$uTH[".,,,
f-: `j_
ATTEST/0/(A CITY SECRETtAIRY ,/O.?
APPROVED AS TO FORM AND LEGALITY:
/ j7ze 'i1-oa
City Attorney Date
EFFECTIVE: 7 3-01
EXHIBIT B
Amendments to the
2003 International Residential Code
The following sections, paragraphs, and sentences of the 2003 International Residential Code for One- and
Two-family Dwellings are hereby amended as follows:
(Standard type is text from the IRC. Underlined type is text inserted. Lined through type is deleted text from
~ After each amendment a reason is given in parentheses. The reason is not a part of the code, but is
given to aid in understanding of the code.
Section R101.1; Insert city name as follows:
R1 01.1 Title. These regulations shall be known as the Building Code of The City of South lake, Texas
hereinafter referred to as "this code."
Section R102.4; change to read as follows:
R102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced
in this code shall be considered part of the requirements of this code to the prescribed extent of each such
reference. Whenever amendments have been adopted to the referenced codes and standards, each
reference to said code and standard shall be considered to reference the amendments as well. Any reference
made to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. Where differences
occur between provisions of this code and referenced codes and standards, the provisions of this code shall
apply
Exception: Where enforcement. . .{remainder of exception unchanged.}. . . .
(Reason: Legal wording to recognize locally adopted codes and amendments adopted with
referenced codes by separate ordinances.)
Section R105.1, Add the following sentence:
105.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move,
demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove,
convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by
this code, or to cause any such work to be done, shall first make application to the building official and obtain
the required permit. For excavation or qradinq permits see IBC appendix chapter J as adopted.
(Reason: to make it clear that grading is regulated under the IBC even if on a residential lot.)
Section R105.2, Under electrical; change as follows:
Electrical. An electrical permit shall not be required for the followinq:
1. Portable motors or other portable appliances enerqized by means of a cord or cable havinq an attachment
pluq end to be connected to an approved receptacle when that cord or cable is permitted by the Electrical
Code.
2. Repair or replacement of fixed motors, transformers or fixed approved appliances of the same type and
ratinq in the same location.
3. Temporary decorative liqhtinq.
4. Repair or replacement of current-carryinq parts of any switch, contactor or control device.
5. Reinstallation of attachment pluq receptacles, but not the outlets therefor.
6. Repair or replacement of any overcurrent device of the required capacity in the same location.
7. Tapìnq joints.
8. Removal of electrical wirinq.
9. Electrical wirinq, devices, appliances, apparatus or equipment operatinq at less than 25 volts and not
capable of supplyinq more than 50 watts of enerqy. ...
10. Low-enerqy power, control and siqnal circuits of Class II and Class III as defined In the Electrical Code.
(Reason: Language from former UAC is more specific.)
Section R105.3.1.1 revise as follows:
§RR105.3.1.1 Substantially improved or substantially damaged existing buildings in are~s 'prone to
flooding. For applications for reconstruction, rehabilitation, addition, or the improvement of existing buildings
or structures located in an area prone to flooding as established by Ordinance 641, the building official shall
examine or cause to be examined the construction documents and shall prepare a finding with regard to the
value of the proposed work. Construction in such areas shall only be permitted as authorized by such
ordinance.
(Delete balance of paragraph)
(Reason: to recognize local flood hazard ordinance)
Section 108.6; add.
108.6 Re-inspection Fee. A fee as established by city council resolution may be charged when:
1. The inspection called for is not ready when the inspector arrives;
2.The temporary electrical pole does not have a building permit clearly posted;
3.No building address or permit card is clearly posted;
4.City approved plans are not on the job site available to the inspector;
5.The building is locked or work otherwise not available for inspection when called;
6.The job site is red-tagged twice for the same item;
7.The original red tag has been removed from the job site and/or,
8.Violations exist on the property including failure to maintain erosion control, trash
control or tree protection.
Any re-inspection fees assessed shall be paid before any more inspections are made on
that job site.
(Reason: This fee is not a fine or penalty but is designed to compensate for wasted time and trips
when inspections are called for when not ready.)
Section 108.7; add.
108.7 Investigation Fee. Work without a permit.
108.7.1 Investigation. Whenever work for which a permit is required by this code has been
commenced without first obtaining a permit, a special investigation shall be made before a
permit may be issued for such work.
108.7.2 Fee. An investigation fee, in addition to the permit fee, shall be collected whether or
not a permit is subsequently issued. The investigation fee shall be equal to the amount of
the permit fee required by this code or the city fee schedule as applicable. The payment of
such investigation fee shall not exempt the applicant from compliance with all other
provisions of either this code or the technical codes nor from penalty prescribed by law.
(Reason: This fee is not a fine or penalty but is designed to compensate for wasted time and to
remove incentive to attempt to evade permits and code compliance. Language taken from former
Uniform Administrative Code.)
Section R109.1.3; change to read as follows:
R1 09.1.3 Floodplain inspections. For construction permitted in areas prone to flooding as established by
Ordinance 641, upon. . . {bulk of section unchanged} . . . construction, the building official may sRaU require
submission. . . {remainder of section unchanged}.
(Reason: Confirmation of elevation is left to local codes.)
Section R110 (R 11 O. 1 through R110.4); delete.
(Reason: Issuing CO's for residences is not a common practice in the area.)
Section 112; delete entirely and substitute the following:
SECTION 112 BOARD OF APPEALS
112.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the
buildinq official relative to the application and interpretation of this code, there shall be and is hereby created a
board of appeals. The Buildinq Board of Appeals as established by ordinance 622, as amended, shall
constitute the Board of Appeals referenced in this code.
112.2 Limitations on authority. An application for appeal shall be based on a claim that the true intent of this
code or the rules leqally adopted thereunder have been incorrectly interpreted, the provisions of this code do
not fully apply, or an equally qood or better form of construction is proposed. The board shall have no authority
to waive requirements of this code.
(Reason recognize appeal board previously established by ordinance.)
Section R112.2.1 and Section R112.2.2; delete.
(Reason Floodplain provisions are addressed by local ordinance.)
Section R202; add definition of "Naturally durable wood" as follows:
NATURALLY DURABLE WOOD. The heartwood of the followinq species with the exception that an
occasional piece with corner sapwood is permitted if 90 percent or more of the width of each side on which it
occurs is heartwood.
Decav resistant. Redwood, cedars. black locust and black walnut.
Termite resistant. Redwood and Eastern red cedar.
Table R301.2(1); fill in as follows:
GROUND SNOW LOAD
5 ¡b/ft
SEISMIC DESIGN CATEGORY"-
A
Weatherin a
moderate
WINTER DESIGN ICE SHIELD UNDER- FLOOD AIR FREEZING MEAN ANNUAL
TEMpff LAYMENT REOUIREDib HAZARDSJ.g INDEX!! TEMpkj
noF No local code 69°F 64.9°F
For SI 1 pound per square foot = 0.0479 kN/m.02, 1 mile per hour = 1.609 km/h.
a. No revisions.
b. No revisions.
c. No revisions.
d. The jurisdiction sh:)11 fill in this p3rt of tho table with "modorate to sever," "slight to moder:)te," or
"nono to slight" in accordance with Figure R301.2(7) dopending on whother there has been a history of
loc:)! damage.
e ,Çt No further revisions.
f e. No further revisions.
€I L No further revisions.
4 ~ No further revisions.
¡ .b..o... No further revisions.
t L No further revisions.
K L No further revisions.
(Reason: To promote regional uniformity. The portion of the table dealing with decay is deleted
because the decay protection provisions in R319 and R320 are uniformly applicable.)
Figure R301.2(7); delete and renumber figures as needed.
(Reason: Corresponds with the amendment to Table R301.2(1 ).)
Section R302. 1; add a second exception as follows:
Exception~:
.L Tool and storage sheds, playhouses and similar structures exempted from permits by Section
R105.2 are not required to provide wall protection based on location on the lot. Projections beyond
the exterior wall shall not extend over the lot line.
2. Open metal carport structures may be constructed within zero (0) feet of the property line without
fire-resistive or openinq protection when the location of such is approved as required by other
adopted ordinances.
(Reason Refers to other ordinances. such as zoning ordinances.)
Section R303.3, exception; change to read as follows:
Exception: The glazed areas shall not be required where artificial light and a mechanical ventilation
system, complyinq with one of the followinq, are provided.
-1-,- The minimum ventilation rates shall be 50 cfm (23.6 LIs) for intermittent ventilation or 20 cfm (9.4
LIs) for continuous ventilation. Ventilation air from the space shall be exhausted directly to the
outside.
2. Bathrooms that contain only a water closet, lavatory or combination thereof may be ventilated with
an approved mechanical recirculatinq fan or similar device desiqned to remove odors from the air.
(Reason: Consistent with common local practice.)
Section R303.8; change to read as follows:
R303.8 Required heating. VVhen the '.'inter design temperature in Table R301.2(1) is below 60e-F-fWeq
evefJ' Every dwelling unit shall be provided with heating facilities capable of maintaining a minimum room
temperature of 6SoF (20°C) at a point 3 feet (914 mm) above the floor and 2 feet (610 mm) from exterior walls
In all habitable rooms at the design temperature.
Section 313; change title as follows:
SECTION R313
FIRE PROTECTION SYSTEMS
(Smoke Alarms and Automatic Fire Extinguishing Systems)
Section313.3; Add sections313.3, 313.3.1 and 313.3.2 as follows:
R313.3 Automatic Fire Extinquishinq Systems
R313.3.1 Standards. Fire protection systems shall comply with the
appropriate International euildinQ Code standards and National Fire
Protection Association standards. (See lec section 903.3.1 throuQh
903.3.1.31
R313.3.2 Where reQuired. An automatic fire-extinquishinq system shall be installed in Group R3 Occupancies
when the dwellinq contains over 6000 square feet conditioned livinq space. For the purpose of this subsection,
area separation walls or fire barriers shall not be considered as forminQ separate buildinqs.
Exceptions: 1. Dwellinqs existinq as of January 5,2001.
2. Any dwellinq may be enlarqed one time without addinq sprinklers, so lonq as the
increase in square feet of conditioned space does not exceed 20% of the existinq
dwellinq.
(Reason: Consistent with present practice.)
Section R318; delete.
(Reason: Vapor barriers are not recommended in this region.)
Sections R319 and R320; change to read as follows:
Revise Section R319.1 and add R319.1.1 to read as follows:
R319.1 Location required. In areas subjoct to decay damage as ostJblished by Figure R3001.2(7),
Protection from decay shall be provided in the following locations shJl1 require Qy the use of naturally
durable wood or an approved species and grade of lumber, wood that is pressure preservativelv
treated in accordance with AWPA C1, C2, C3, C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1,
P2, and P3. or decay resistant heartwood of redwood, black locust, or cedars
1. No revision.
2. No revision.
3. No revision.
4. No revision.
5. No revision.
6. No revision.
7. No revision.
R319.1.1 Field treatment. Field cut ends, notches and drilled holes of pressure preservativelv treated
wood shall be retreated in the field in accordance with AWPA M4.
Renumber existing sections R319.1.1 (Ground contact) through R319.1.4 (Wood columns).
Delete Section R320.1 and substitute the following:
R320.1 Subterranean termite control. In areas favorable to termite damage as established by Table
R 301.2 (1), methods of protection shall be by one of the followinq: ChomicJI soil troJtment, pros£uro
preservati'loly treated wood in accordance with tho I\VVP^ £tJndards li£ted in Soction R319.1,
naturally termite resistant 'Nood or phy£ical barrior£ (such a£ metal or pla£tic termite £hields), or any
combination of these methods.
R 320.1.1 Pressure preservativelv treated or naturally durable wood shall be provided as per
HUD standards. Pressure perservativelv treated wood shall be treated in accordance with the
standards cited in R 319.1.
R 320.1.1.1 RJ20.1.1 Quality Mark. Lumber and plywood required to be pressure
preservatively treated in accordance with R324.1 shall bear the quality mark of an approved
inspection agency which maintains continuing supervision, testing, and inspection over the
quality of the product and which has been approved by an accreditation body which complies
with the requirements of the American Lumber Standards Committee treated wood program.
R320.1.1.2 Field treatment. Field cut ends, notches and drilled holes of pressure
preservativelv treated wood shall be retreated in the field in accordance with AWPA M4.
Revise sections R320.2 through R320.4 as follows:
R320.2 R320.1.2 Chemical soil Pesticide treatment. The concentrations, rate of application
and treatment methods of the termiticide shall be consistent with and never less than the
termiticide label. Pesticide treatment shall be provided usinq methods approved by the
Environmental Protection Aqencv and the Texas Structural Pest Control Board.
R320.1.3 Physical Barriers. Physical barriers shall be installed as
recoqnized by Texas Structural Pest Control Board.
RJ20.3 Pressure preservati'lely treated ,,'¡ood and naturally resistant wood. Hoartwood of
redwood and eastern red cedar shall be considered termite resistant. Pres£uro preservatively treated
wood and naturally termite re£i£tant INood shall not bo u£ed as a phy£ical barrier unlo££ a barrier can
bo inspected for any termite shelter tubo£ around the in£ide and out£ido edges Jnd joint£ of a barrier.
R320.3.1 Field treatment. Field cut ends, notches and drilled holes of pressure
pre£orvatively treated wood shall be retreated in tho field in Jccordance 'Nith AWPI\ M'1.
RJ20.4 R320.2 Foam plastic protection. {Remainder of section unchanged.}
(Reason: To make the IRC decay protection requirements consistent with the IBC and consistent
with similar provisions that were contained in the UBC. Reference is added in R320 for treating of
field cuts in compliance with AWPA M4. This is consistent with the requirements in R319. However,
In practice almost all preservatively treated wood in the local area is southern pine and Section 6 of
M4 says that field treatment of softwood species such as southern pine isn't necessary to provide a
good service life.
The revisions to R320 are intended to make the section read better and to provide guidance in
proper methods of termite protection.)
Section R323. 1; change to read as follows:
R323.1 General. Buildings and structures, when permitted to be constructed in flood hazard areas. . . {bulk of
section unchanged}. . shall be designed and constructed as required in accordance with the provisions
contained in this section or by other local provisions as applicable.
(Reason Recognize other local provisions.)
Section R602.10.5; add the following exception and figure:
Exception: Vertical wall seqments in the first of one- or first of two-story buildinqs next to qaraqe openinqs
shall be permitted to have a 6: 1 heiqht-to-width ratio (with heiqht beinq measured from top of header to sill
plate) when constructed in accordance with the followinq provisions. Each panel shall have a lenqth of not
less than 16 inches (406 mm) and a heiqht of not more than 10 feet (3048 mm). Each panel shall be sheathed
on one face with a sinqle layer of 3/8-inch-minimum-thickness (9.5 mm) wood structural panel sheathinq nailed
with 8d common or qalvanized box nails in accordance with Fiqure R602.1 0.5(2). The wood structural panel
sheathinq shall extend up over the solid sawn or qlued-Iaminated header and shall be nailed in accordance
with Fiqure R602.1 0.5(2). The header shall extend between the inside faces of the first full-Ienqth outer studs
of each panel. The clear span of the header between the inner studs of each panel shall be not less than six
feet (1829 mm) and not more than 18 feet (5486 mm) in lenqth. A strap with an uplift capacity of not less than
1000 pounds (454 kq) shall fasten the header to the side of the inner studs opposite the sheathinq. Two
anchor bolts shall be installed in accordance with Section R403.1.6, and plate washers shall be a minimum of
2 Inches by 2 inches by 3/16 inch (51 mm by 51 mm by 4.88 mm) thick and shall be used on each bolt. This
exception is only permitted in Seismic Desiqn Cateqories A-C.
FiQure R602.1 0.5(2)
GARAGE DOOR BRACED WALL PANEL FOR USE WITH CONTINUOUSLY SHEATHED WALLS
~
I
EX.TENT OF HEADER
I
~ ~ [LU
. !i~ ':i
3l'ÇJ' MIN. THICf<NESSWOOD ~¡: ¡.:
STRUCTURAL PANEL SHEATHING :~ :-i
.i':.,
,IJ .~
MN.(2)2A ---_'.i~ i.j
t,':'i
:.H :.1
MN. 2<4 ~
FRAMING'i" ;'j
TYP. '.':~:.
J;rr !,
/:::: i~
/ )J.i
FOR A PANEL SPUCE (IF NEEDED), PANEL / :-i-¡ ¡.:
EDGES SHALLBE BLOCKED, AND OCCUR ::~! ;::'
',J\iITHIN 24" OF MD-HEIGHT. ONE ROW OF !':l:~: ¡.j
TYP SHEATHING TO.FRA.MING NAJUNG IS ¡'j
REQUIRED i:::: i:i
IF 2/:48LOU<JNG IS USED, THE2X:4'S i.V '.i.
MUST 8E I,AJLED TDGETHER \I\IITH 31ôD ;.~¡ ).
SINKERS
MIN. :0:' X H2B' NET HEADER
I
I
I
I
I
I
I
!
~~.
.u -....
:~: -- ---~ FASTEN TOP PLA.TE TO HEADER WITH TWO
;I: Rmni:::; OFlôD SINKER ftAJLSAT3" O.C TYP
-fJ TO 18'
'.
10:0 L8 STRÞ? OPPOSITE SHEA.THlr~G
r"tAx-
HEIGHT
1(1
FASTEr. SHE.A.THING TO HEADER WITH 8D
COM~.oN OR GÞlVÞNCED 80:< I-/AIL:::; IN 3' GRID
PA.TTEF:I, AS SHOWN MW 3" O.C IN ,ALL
FRAMING C:::;TUD::', 8LOCkJNG, .A.I,D :;ILLS) TYP
---~~ \JìiIDTH BASED ON ô:1 HEIGHT. TO-WIDTH RÞ.TICi.
FOR12C1'HEIGHT,MIN.'ifl'WTH=2C1' FORgô"
HEIGHT, MIl< \1\![:oTH = 1t1', ETC
:~
:" -----
,I. ------. Mill 12) 24
,,:
- T(PICALCORNER DETÞJL
F'ER FIGURE Re02.m.',
"
.;,
~~~ SEE SECTION F:4û3.1.f¡
t
r
l
(Reason: To provide an alternate means of compliance,)
Section R703. 7.4. 1; add a second paragraph to read as follows:
.For 3% square feet (0,302 m2) of wall area, the foliowinQ dimensions shall be adhered to:
1, When ties are placed on studs 16" o.c" they shall be spaced no further apart than 29" vertically startinQ
approximately 15" from the foundation.
2 When ties are placed on studs 24" o,c" they shall be spaced no further apart than 19" vertically startinq
approximately 10" from the foundation,
(Reason: for clarity, specific dimensions are easier to understand, eliminates need for calculations by
masons. )
Add Section R902.3 to read as follows:
R902.3 Minimum Roof Class. All roof coverinqs shall be a minimum Class C. All individual replacement
shinqles or shakes shall be a minimum Class C.
Exception: Non-classified roof coverinQs shall be permitted on buildinqs of U occupancies havinq not
more than 120 sQ.ft, of proiected roof area, When exceedinq 120 sQ.ft, of projected roof area,
buildinqs of U occupancies may use non-rated non-combustible coverinqs.
(Reason: Consistent with local practice.)
Section R905. 7. 1; amend as follows:
R905.7.1 Deck requirements. Wood shingles shall be installed on solid or sp3ced sheathing. Whore sp3cod
sh03thing is used, sheathing boards shall not be less than 1 inch by 1 inch (25.1 mm by 102 mm) nominal
dimensions and sh::¡11 bo sp3cod on centers equal to the weather exposure to coincide with the pl::¡comont of
fasteners,
905.7.1.1 Solid sheathing required,
In 3reas where tho average daily tempor3turo in January is 25°F ( 1°C) or loss, solid sheathing is required on
that portion of the roof requiring the application of 3n ice shield, . ,
(Reason: Spaced sheathing burns more quickly when ignited. Spaced sheathing must be replaced If
homeowner needs to replace roof covering,)
Section R907. 1; add a sentence to read as follows:
R907.1 General. Materials and methods of application used for recovering or replacing an existing roof
covering shall comply with the requirements of Chapter 9. All individual replacement shinqles or shakes shall
comply with Section R902.3.
Exception: Reroofing shall not be required to meet the minimum design slope requirement of one-
quarter unit vertical in 12 units horizontal (2- percent slope) in Section 905 for roofs that provide positive
roof drainage.
(Reason: Consistent with local practice. Correlates with regional amendment to R902.3.)
Section N1101.2; amend as follows:
N1101.2.1 Detached one- and two-family dwellings.
Compliance shall be demonstrated by either:
1 Meeting the requirements of this chapter for buildings with a glazing area that does not exceed 15 percent of
the gross area of exterior walls; or
2 Meeting the requirements of the International Energy Conservation Code for detached one- and two-family
dwellings~
3. Meetinq the requirements of this chapter for buildinqs with a qlazinq area that is qreater than 15 percent
but not exceedinq 20 percent of the qross area of exterior walls and air conditioninq equipment rated 12 SEER
or hiqher; or
4. Meetinq the requirements of this chapter for buildinqs with a qlazinq area that is qreater than 20 percent
but not exceedinq 25 percent of the qross area of exterior walls and air conditioninq equipment rated 14 SEER
or hiqher.
(Reason: This amendment increases the number of builders who could use this "simplified
prescriptive" approach of the IRC. The trade-off with air-conditioning is an option under the IECC
systems analysis or REScheck approach, and is brought into this format for convenience only.
Other IECC trade-offs would also remain available. The intent is to maintain compatibility with the
IECC. The intent would include adjustment of this provision at such future date that the minimum
federal equipment standards are raised to achieve equivalent increases in energy savings.)
Add Section N1101.3.4 to read as follows:
N11 01.3.4 Exterior basement or slab insulation. When susceptibility to termite damaqe is classified as
"very heavy" accordinq to Table R301.2(1), desiqns employinq basement or slab exterior insulation capable of
harborinq termites shall not be utilized.
(Reason: Usage of exterior insulation provides access for termites. This amendment does not
preclude the use of insulating coatings that do not provide termite access or shelter.)
Section N1102.1; amend as follows:
N1102.1 Thermal performance criteria. The minimum required insulation R-value or the area-weighted
average maximum required fenestration U-factor (other than opaque doors which are governed by Section
N11 02.13) for each element in the building thermal envelope (fenestration, roof/ceiling, opaque wall, floor,
slab edge, crawl space wall and basement wall) shall be in accordance with the criteria in Table N11 02.1.
Detached one-and-two family dwellings with greater than 4-á-25-percent glazing area; townhouses with greater
than 25-percent glazing area; and any residential building in climates 'Nith heating degree days equ:::¡1 to or
greater th:::¡n 13,000; shall determine compliance using the building envelope requirements of Chapters 4 or 5
of the International Energy Conservation Code.
(Reason This amendment is compatible with the amendment to Section N11 01.2.1, which increases the
allowable glazing area and effectively increases the number of builders who can use the "simplified
prescriptive" approach of the IRC.)
Replace Table N1102.1 with:
TABLE N1102.1
MINIMUM INSULATION R-VALUE [(hr.ff."F)/Btu]
Ceilings Ceiling
MAXIMUM open to Joist/Roof Walls Floors Basement Slab Crawl
GLAZING Attic Rafter Walls perimeter space
U-FACTOR Space Assembly walls
[Btu/(hr-W.oF)]
0.65 R-38 R-22 R-13 R-19 R-O R-O R-7a
SIMPLIFIED PRESCRIPTIVE BUILDING ENVELOPE THERMAL COMPONENT CRITERIA
MINIMUM REQUIRED THERMAL PERFORMANCE (U-FACTOR AND R-VALUE)
a. Crawl space insulation is only required for structures with uninsulated floors.
Use of this table is limited to projects where the cathedral ceiling area is limited to one third or less of the total
ceiling area.
(Reason: These numbers are from the tables in the code for the climate data of the Dallas/ Ft. Worth
area. This amendment is compatible with the previous amendments increasing the number of
builders who could use the "simplified prescriptive" approach of the IRC and incorporates the Home
Builder Association prescriptive package proposal. The addition of "Ceiling Joist/Roof Rafter
Assembly" requirements protect such assemblies from the damage likely to occur if greater amounts
of insulation were attempted in such assemblies.)
Section N1102.1.6; delete last sentence of exception.
(Reason: Slab edge insulation is not recommended in this region. Deleting the last sentence of the
exception allows the use of the simplified prescriptive method of compliance.)
Section N1102.2; add exceptions as follows:
N1102.2 Maximum solar heat gain coefficient for fenestration products. The area-weighted-average solar
heat gain coefficient (SHGC) for glazed fenestration installed in locations with 3,500 or fewer heating degree
days shall not exceed 0.40.
Exceptions:
1. Any QlazinQ facinQ within 45 deQrees of true north;
2. Any QlazinQ facinQ within 45 deQrees of true south which is shaded alonQ its full width by a
permanent overhanq with a proiection factor of 0.3 or Qreater.
3. Any fenestration with permanently attached screens where the screens have a rated shadinQ
coefficient of .6 or less.
(Reason: This will allow north facing windows, which do not receive direct solar radiation, to be
exempt from the minimum SHGC requirement; provides a simple way for south facing windows to
effectively achieve summer shade and still receive some solar heat benefit in winter; and specifically
allows use of solar screens to achieve the shading effect.)
Table N1103.5; amend as follows:
Amend footnote "b" to read as follows:
b. For piping lenqths in excess of five (5) feet (1,524 mm) exposed to outdoor air, increase thickness
by 0.5 inch (13 mm).
(Reason: No performance data is available. REM/Rate scoring procedures do not c~ns.ider
refrigerant piping insulation. This amendment will provide a uniform approach and eliminate the
requirement of policies by the various jurisdictions.)
Add Section M1304.2 to read as follows:
M1304.2 Minimum burial depth, Underqround fuel pipinq systems shall be installed a minimum depth of 18
inches (458 mm) below qrade.
(Reason: Appropriate protection consistent with area practice.)
Section M1305.1.3; change to read as follows:
M1305.1.3 Appliances in attics. Attics containing appliances requiring access shall be provided. . . {bulk of
paragraph unchanged} . . . from the opening to the appliance. The passageway shall have continuous
unobstructed solid flooring not less than;M- 30 inches (ê-:W 762 mm) wide. A level service space not less than
30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present at the front or service side of the
equipment. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by
762 mm), or larqer where such dimensions are not large enough to allow removal of the largest appliance. As
a minimum, access to the attic space shall be provided by one of the followinq:
1. A permanent stair.
2. A pull down stair.
3. An access door from an upper floor level.
Exception: The passageway and level service space are not required where the appliance is capable
of being serviced and removed through the required opening.
(Reason: To provide a safe means of accessibility to appliances in attics. Consistent with regional
amendments to IMC 306.3 and IFGC 306.3.)
Add Section M1305.1.5, M1305.1.5.1 to read as follows:
M1305,1.5 Water heaters above ç¡round or floor. When the mezzanine or platform in which a water heater
IS installed is more than eiqht (8) feet (2438 mm) above the qround or floor level, it shall be made accessible
by a stairway or permanent ladder fastened to the buildinq.
M1305.1.5.1 Whenever the mezzanine or platform is not adequately liqhted or access to a receptacle
outlet is not obtainable from the main level, liqhtinq and a receptacle outlet shall be provided in
.accordance with Section M1305.1.3.1.
Section M1305.1.3.1; add a sentence to read as follows:
Low voltaqe wirinq of 50 Volts or less shall be installed in a manner to prevent physical damaqe.
Section M1305. 1.4. 1; change to read as follows:
M1305.1.4.1 Ground clearance. Appliances supported from the ground shall be level and firmly supported on
a concrete slab or other approved material extending above the adjoining grade a minimum of 3 inches (76
mm) Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) above
the ground.
Section M1305.1.4.3; add a sentence to read as follows:
Low voltaqe wirinq of 50 Volts or less shall be installed in a manner to prevent physical damaqe.
Section M1307.3.1; delete.
Section M1501.2; change to read as follows:
M1501.2 Exhaust duct size. The minimum diameter of the exhaust duct shall be as recommended by the
manufacturer" aAG shall be at least the diameter of the appliance outlet and shall be a minimum nominal size of
4 inches (102 mm) in diameter. The size of duct shall not be reduced alonq its developed lenqth nor at the
point of termination.
Section M1501.3; change to read as follows:
M1501.3 Length limitation. The maximum length of a clothes dryer exhaust duct shall not exceed 25 feet
(7620 mm) from the dryer location to the wall or roof termination. The maximum length of the duct shall be
reduced 2.5 feet (762 mm) for each 45-degree (0.79 rad) bend and 5 feet (1524 mm) for each 90-degree (1.6
rad) bend. The maximum length of the exhaust duct does not include the transition duct.
Exceptions: (see next page)
Exceptions:
1. Where a clothes dryer booster fan is installed and listed and labeled for the application,
the maximum length of the exhaust duct, including any transition duct, shall be permitted to
be in accordance with the booster fan manufacturer's installation instructions. Where a
clothes dryer booster fan is installed and not readily accessible from the room in which the
dryer is located, a permanent identifying label shall be placed adjacent to where the exhaust
duct enters the wall. The label shall bear the words "This dryer exhaust system is equipped
with a remotely located booster fan."
2. Where the make and model of the clothes dryer to be installed is known and the
manufacturer's installation instructions for such dryer are provided to the building official, the
maximum length of the exhaust duct, including any transition duct, shall be permitted to be
in accordance with the dryer manufacturer's installation instructions.
3. Where the first 9 feet of vent are 4" diameter pipe with not over two 900 bends and the pipe size is
then increased to 5" diameter, it may extend horizontally as far as 28.5 feet to the termination
outdoors.
(Engineered dryer vent equivalent considering velocity and pressure drop.)
Section M1601.3.4, item #1; change to read as follows:
1. Duct insulation shall conform to the requirements of Table M1601.3.4 and Section N11 01.2. Should there
be any conflicts between this section and the enerqy efficiency provisions, the enemy efficiency provisions
shall take precedence.
A vapor retarder in accordance with Table M1601.3.4 having a maximum permo~1nce of 0.05 perm [2.87
R§It&--m~ P:J)] in 3ccord:Jnce with ,^,STM E 96, or aluminum foil having a minimum thickness of 2 mils
(0.051 mm), shall be installed on the exterior of insulation on cooling supply ducts that pass through
nonconditioned spaces conducive to condensation.
Insulations havinq a permeance of 0.05 perms [2.87 nqJ(Pa . s . m2)1 or less shall not be required to be
covered.
(Reason: To indicate presiding code and reference to Table M1601.3.4. See next amendment.)
Add Table M1601.3.4 to read as follows:
Duct Location
Table M1601.3,4 -Insulation of Ducts
Insulation Types4
Mechanically
Cooled
Heating Zone 1
i On roof on exterior of building
C, V2 and W
I
II
III
Insulation
Types4
Heating Only
A and W
Band W
C and W
!
I Attics, garages and crawl spaces
(
I'n walls', within flam-ceiling spaces'
I Within the conditioned space or in
I basements; return ducts in air plenums
i Cement slab or within ground
L-
A and V2
I
II
III
A
A
B
A and V2
I
II
III
A
A
B
None required
None required
None required
None required
Note: Where ducts are used for both heating and cooling, the minimum insulation shall be as required for the
most restrictive condition.
1 Heating Degree Days:
Zone I below 4,5000.0 Zone II 4,501 to 8,000 D.o. Zone III over 8,000 D.O.
2 Vapor retarders shall be installed on supply ducts in spaces vented to the outside in geographic areas where
the summer dew point temperature based on the 2 % percent column of dry-bulb and mean coincident wet-
bulb temperature exceeds 60° F. (15.4° C).
3 Insulation may be omitted on that portion of a duct which is located within a wall- or a floor-ceiling space
where.
" Both sides of the space are exposed to conditioned air.
32 The space is not ventilated.
33 The space is not used as a return plenum.
34 The space is not exposed to unconditioned air.
Ceilings which form plenums need not be insulated.
4 INSULATION TYPES:
A -- A material with an installed conductance of 0.48 [2.72 W/(m*K)] or the equivalent thermal resistance of
2.1 [0.367 (m*K)/W].
Example of materials capable of meetin~ the above requirements:
1-inch (25 mm), 0.60 Ib.lcu.ft. (9.6 kg 1m ) mineral fiber, rock, slag or glass blankets.
'2-inch (13 mm), 1.5 to 3 Ib.lcu.ft. (24 to 48 kg/m3) mineral fiber blanket duct liner.
'2-inch (13 mm), 3 to 10 Ib.lcu.ft. (48 to 160 kg/m3) mineral fiber board.
B -- A material with an installed conductance of 0.24 [1.36 W/(m*K)] or the equivalent thermal resistance of
4.2 [0.735 (m*K)/W].
Example of materials capable of meetin~ the above requirements:
2-inch (51 mm), 0.60 Ib.lcu.ft. (9.6 kg/m ) mineral fiber blankets.
1-inch (25 mm), 1.5 to 3 Ib.lcu.ft. (24 to 48 kg/m3) mineral fiber blanket duct liner.
1-inch (25 mm), 3 to 10 Ib.lcu.ft. (48 to 160 kg/m3) mineral fiber board.
C -- A material with an installed conductance of 0.16 [0.9 W/(m*K)] or the equivalent thermal resistance of
6.3 [1.1 (m*K)/W].
Example of materials capable of meetin~ the above requirements:
3-inch (76 mm), 0.60 Ib.lcu.ft. (9.6 kg/m ) mineral fiber blankets.
1 '/;,-inch (38 mm), 1.5 to 3 Ib.lcu.ft. (24 to 48 kg/m3) mineral fiber blanket duct liner.
1 Y2-inch (38 mm), 3 to 10 Ib.lcu.ft. (48 to 160 kg/m3) mineral fiber board.
V --Vapor Retarders: Material with a perm rating not exceeding 0.05 perm [29 ng/Pa*s*m2]. All joints to be
sealed.
W -Approved weatherproof barrier.
¡ The example of materials listed under each type is not meant to limit other available thickness and density
combinations with the equivalent installed conductance or resistance based on the insulation only.
(Reason: To reduce heating and/ or cooling energy duct losses. Designed for this climate zone.)
Section M2005.2; change to read as follows:
M2005.2 Prohibited locations. Fuel-fired water heaters shall not be installed in a room used as a storage
closet. Water heaters located in a bedroom or bathroom shall be installed in a sealed enclosure so that
combustion air will not be taken from the living space. Access to such enclosure may be from the bedroom or
bathroom when throuqh a solid door, weather-stripped in accordance with the exterior door air leakaqe
requirements of the International Enerqv Conservation Code and equipped with an approved self-closinq
device. Direct-vent water heaters are not required to be installed within an enclosure.
(Reason: Corresponds with the provisions of IFGC Section 303, exception #5.)
Section G2403; amend definition of "Unvented Room Heater" to add a sentence to read as follows:
For the purpose of installation, this definition shall also include "Unvented Decorative Appliances."
(Reason Clarifies installation for these devices.)
S~ction G2412.5; add a second paragraph to read as follows:
G2412,5 (401.5) Identification. For other than black steel pipe, exposed piping shall be identified by a yellow
label marked "Gas" in black letters. The marking shall be spaced at intervals not exceeding 5 feet (1524 mm).
The marking shall not be required on pipe located in the same room as the equipment served.
Both ends of each section of medium pressure qas pipe or tubinq shall identify its operatinq qas
pressure with an approved taq. The taqs are to be composed of aluminum or stainless steel and the followinq
wordinq shall be stamped into the taq:
"WARNING
1/2 to 5 psi qas pressure
Do Not Remove"
(Reason: To protect homeowners and plumbers.)
Section G2413.3; add an exception to read as follows:
Exception: Corruqated stainless steel tubinq (CSST) shall be a minimum of 1/2".
(Reason: Pipe less than 1/2" has a history in this region of causing whistling.)
Section G2415.6; change to read as follows:
G2415.6 (404.6) Piping in solid floors. Piping in solid floors shall be laid in channels in the floor and
covered in a manner what will allow access to the piping with a minimum amount of damage to the building.
Where such piping is subject to exposure to excessive moisture or corrosive substances, the piping shall be
protected in an approved manner. As an alternative to installation in channels, the piping shall be installed in
accordance with Section G241 5.11 (404.11) a casing of schedule '10 steel, wrought iron, PVC or ABS pipe with
tightly sealed ends and joints. Both ends of such casing sh::J11 extend not less th::Jn 2 inches (51 mm) beyond
the point where the pipe emerges from the floor.
(Reason Referencing Section G2415.11 provides CSST piping with outside venting.)
Section G2415.9; change to read as follows:
G2415.9 (404.9) Minimum burial depth. Underground piping systems shall be installed a minimum depth of
~.lli inches (ðGá 458 mm) below grade, except as provided for in Section G21 15.9.1.
(Reason To provide increased protection to piping systems.)
Section G2415.9.1; delete.
(Reason: Individual lines should also be buried to 18 inches.)
Section G2417.4; add a sentence to read as follows:
G2417.4 (406.4) Test pressure measurement. Test pressure shall be measured with a manometer or with a
pressure measuring device designed and calibrated to read, record, or indicate a pressure loss caused by
leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are
made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the
scale is not greater than five times the test pressure. The equipment used shall be of an appropriate scale
such that pressure loss can be easily determined.
(Reason To stress need for appropriate test equipment.)
Section G2417.4.1; change to read as follows:
G2417.4.1 (406.4.1) Test pressure. The test pressure to be used shall be not less than one and one half
times the proposed maximum '.'larking pressure, but not less than 3.1Q psig (2G 68.9 kPa gauge), or at the
discretion of the Code Official, the pipinq and valves may be tested at a pressure of at least six (6) inches (152
mm) of mercury, measured with a manometer or slope qauqe. irrespective of design pressure. Where the test
pressure exceeds 125 psig (862 kPa g::Juge), the test pressure shall not exceed a v::Jlue that produces a hoop
stress in the piping greater th3n 50 percent of the specified minimum yield strength of the pipe. For welded
plpinq, and for pipinq carryinq qas at pressures in excess of fourteen (14) inches water column pressure (3.48
kPa), the test pressure shall not be less than sixty (60) pounds per square inch (413.4 kPa).
Section G2417.4.2; change to read as follows:
G2417.4.2 (406.4.2) Test duration. Test duration shall be held for a lenqth of time satisfactory to the Code
Official, but in no case for ¡::¡ffi less than -iG fifteen (15) minutes. For welded pipinq, and for pipinq carryinq qas
ôt ore55ure5 in excess of fourteen (14) inches water column pressure (3.48 kPa), the test duration shall be
held for a lenqth of time satisfactory to the Code Official, but in no case for less than thirty (30) minutes.
(Reason: In this region, specific test methods were defined in amendments to the 1996 International
Mechanical Code. Amendments to Sections G2416.4.1 and G2416.4.2 retain those standards,
which are now standard practice)
Add Section G2420.1.4 to read as follows:
G2420.1.4 Valves in CSST installations. Shutoff valves installed with corruqated stainless steel (CSST)
pipinq systems shall be supported with an approved termination fittinq, or equivalent support. suitable for the
size of the valves, of adequate strenqth and quality, and located at intervals so as to prevent or damp out
excessive vibration but in no case qreater than 12-inches from the center of the valve. Supports shall be
installed so as not to interfere with the free expansion and contraction of the system's pipinq, fittinqs, and
valves between anchors. All valves and supports shall be desiqned and installed so they will not be
disenqaqed by movement of the supportinq pipinq.
(Reason: To provide proper security to CSST valves. These standards were established in this
region in 1999 when CSST was an emerging technology.)
Section G2421.1; add a second paragraph and exception to read as follows:
G2421.1 (410.1) Pressure regulators. A line pressure regulator shall be installed where the appliance is
designed to operate at a lower pressure than the supply system. Access shall be provided to pressure
regulators. Pressure regulators shall be protected from physical damage. Regulators installed on the exterior
of the building shall be approved for outdoor installation.
Access to requlators shall comply with the requirements for access to appliances as specified in Section
M1305.
Exception: A passaqeway or level service space is not required when the requlator is capable of
beinq serviced and removed throuqh the required attic openinq.
(Reason: To require adequate access to regulators.)
Section G2439.5; add a sentence to read as follows:
The size of duct shall not be reduced alonq its developed lenqth nor at the point of termination.
(Reason: To clarify the size requirement.)
Section G2439.5.1; add a second exception as follows:
G2439.5.1 (614.6.1) Maximum length. The maximum length of a clothes dryer exhaust duct shall not exceed
25 feet (7620 mm) from the dryer location to the outlet terminal. The maximum length of the duct shall be
reduced 21/2 feet (762 mm) for each 45 degree (0.79 rad) bend and 5 feet (1524 mm) for each 90 degree (1.6
rad) bend.
Exceptions:
LWhere the make and model of the clothes dryer to be installed is known and the manufacturer's
installation instructions for such dryer are provided to the code official, the maximum length of the
exhaust duct, including any transition duct, shall be permitted to be in accordance with the dryer
manufacturer's installation instructions.
2. Where the first 9 feet of vent are 4" diameter pipe with not over two 90° bends and the pipe size is
then increased to 5" diameter, it may extend horizontally as far as 28.5 feet to the termination
outdoors.
(Reason Engineered dryer vent equivalent considering velocity and pressure drop.)
Section G2445.2; change to read as follows:
G2445.2 (621.2) Prohibited use. One or more unvented room heaters shall not be used as the sole source of
comfort heating in a dwelling unit.
Exception: Existinq approved unvented heaters may continue to be used in dwellinq units, in
accordance with the code provisions in effect when installed, when approved by the Code Official
unless an unsafe condition is determined to exist as described in International Fuel Gas Code Section
108.7.
(Reason Gives code official discretion.)
Section P2503.5.1, item 1; add a second paragraph to read as follows:
P2503.5.1 Rough plumbing. DWV systems shall be tested on completion of the rough piping installation by
water or air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in
sections after rough piping has been installed, as follows:
1. Water test. Each section shall be filled with water to a point not less than 10 feet (3048 mm) above the
highest fitting connection in that section, or to the highest point in the completed system. Water shall be held in
the section under test for a period of 15 minutes. The system shall prove leak free by visual inspection.
Shower receptors shall be tested for water tiqhtness by fillinq with water to the level of the rouqh threshold.
The drain shall be pluqqed in a manner so that both sides of pans shall be subjected to the test at the point
where it is clamped to the drain.
2 Air test. The portion under test shall be maintained at a gauge pressure of 5 pounds per square inch (psi)
(34 kPa) or 10 inches of mercury column (2488 Pa). This pressure shall be held without introduction of
additional air for a period of 15 minutes.
(Reason. To clarify that a water test is required for a shower receptor.)
Section P2503.7.2; change to read as follows:
P2503.7.2 Testing. Reduced pressure principle. . . {bulk of section unchanged} . . . at the time of installation,
Immediately after repairs or relocation and at reqular intervals as required by the Cross Connection Control
Policy, Ordinance No. 699. least annu31ly.
(Reason: Recognize TECQ or other local testing procedures that must be adhered to.)
Section P2603. 6. 1; change to read as follows:
P2603.6.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum
of twelve (12) inches (304 mm) below finished grade at the point of septic tank connection. Building sewers
shall be a minimum of Rinches (304 mm) below grade.
(Reason Provides sewer depth that is common in this region.)
Section P270B. 1; add a sentence to read as follows:
Shower thresholds shall be of sufficient width to accommodate a minimum twenty-two (22) inch (559 mm)
door.
(Reason: To provide more specific requirements.)
Section P2709. 1; add an exception to read as follows:
Exception: Showers desiqned to comply with ICC/ANSI A 117.1.
Section P2B03. 6. 1; change to read as follows:
P2803.6.1 Requirements of discharge pipe. The outlet of a pressure relief valve, temperature relief valve or
combination thereof, shall not be directly connected to the drainage system. The discharge from the relief
valve shall be piped full size separately to the floor, to the outside of the building or to an indirect waste
receptor located inside the building. In are3!> subject to freezing, the relief v31ve !>hall disch3rge through ::m air
g3p into an indirect 'Naste receptor loc3ted within 3 heated sp3ce, or by other approved mean!>. The discharqe
pipe shall not discharqe into the pan required by section P2801.5.
The discharge shall be installed in a manner that does not cause personal injury or property damage and that
is readily observable by the building occupants. The discharge from a relief valve shall not be trapped. The
diameter of the discharge piping shall not be less than the diameter of the relief valve outlet. The discharge
pipe shall be installed so as to drain by gravity flow and shall terminate atmospherically pointinq downward. AGt
more than 6 inche!> (152 mm) above the floor. When discharqinq outside the buildinq, the point of discharqe
shall not be more than two (2) feet (610 mm) nor less than six (6) inches (152 mm) above the qround or floor
level of the area receivinq the discharqe.The outlet end of the discharge pipe shall not be threaded nor have a
valve Installed.
(Reason To provide a higher degree of safety.)
Table P2904.4.1; delete "Polybutylene (PB) plastic pipe and tubing".
Sections P2904.5, 2904.5.1 and 2904.15; delete reference to "PB" plastic pipe.
(Reason: Polybutylene pipe is not allowed for use in this region.)
Section P3005.2.6; changed to read as follows:
P3005.2.6 Upper terminal Baso of stacks. Each horizontal drain shall be provided with a cleanout at its
upper terminal J\ccessiblo cle3nouts !>h311 be provided ne3r the base of each vertical w3ste or soil ~t~ck.
^ltern3tively, such clean outs m3Y be inst311ed outside tho building within 3 feet (911 mm) of tho bUlldl~g wall.
Exception: Cleanouts may be omitted on a horizontal drain less that five (5) feet (1524 mm) In lenqth
unless such line is servinq sinks or urinals.
(Reason To eliminate the requirement for excessive cleanouts.)
Section P3103.1; changed to read as follows:
P3103.1 Roof extension. All open vent pipes which extend through a roof shall be terminated at least six (6)
Inches (152 mm) above the roof or [number] inches :Jbove the anticipated snow accumul:Jtion, except that. . .
{remainder of section unchanged}.
(Reason: To provide regional guideline on standard installation method for this area.)
Sections P3105.2; change to read as follows:
P3105.2 Fixture drains. The total fall in a fixture drain due to pipe slope shall not exceed one pipe diameter,
nor shall the vent pipe connection to a fixture drain, except for water closets, be below the weir of the trap,
except 3S provided in Section P3105.3.
Section P3105.3 and Figure P3105.3; delete
(Reason: S traps may siphon dry allowing sewer gas into building.)
Section P3111.1; change to read as follows:
P3111.1 Type of fixture. A combination waste and vent system shall not serve fixtures other than floor drains,
standpipes, sffik&-and lavatories indirect waste receptors. Combination drain and vent systems shall not
receive the discharqe of a food waste qrinder.
(Reason To prevent trap siphoning of sinks and lavatories.)
Section P3111.2; change to read as follows:
P3111.2 Installation. The only vertical pipe of a combination drain and vent system shall be the connection
between the fixture drain of a sink, 13v:Jtory or standpipe, and the horizontal combination waste and vent pipe.
The maximum vertical distance shall be 8 feet (2438 mm).
(Reason To prevent trap siphoning of sinks and lavatories.)
Sections P3112.2 and3112.3 ;delete and replace with new Section 3112.2 as follows:
P3112.2 Installation. Traps for island sinks and similar equipment shall be rouqhed in above the floor and
may be vented by extendinq the vent as hiqh as possible, but not less than the drainboard heiqht and then
returninq it downward and connectinq it to the horizontal sink drain immediately downstream from the vertical
fixture drain. The return vent shall be connected to the horizontal drain throuqh a wye-branch fittinq and shall,
in addition, be provided with a foot vent taken off the vertical fixture vent by means of a wye-branch
Immediately below the floor and extendinq to the nearest partition and then throuqh the roof to the open air or
may be connected to other vents at a point not less than six (6) inches (152 mm) above the flood level rim of
the fixtures served. Drainaqe fittinqs shall be used on all parts of the vent below the floor level and a minimum
slope of one-quarter (1/4) inch per foot (20.9 mm/m) back to the drain shall be maintained. The return bend
used under the drainboard shall be a one (1) piece fittinq or an assembly of a forty-five (45) deqree (0.79
radius), a ninety (90) deqree (1.6 radius) and a forty-five (45) deqree (0.79 radius) elbow in the order named.
Pipe sizinq shall be as elsewhere required in this Code. The island sink drain, upstream of the return vent,
shall serve no other fixtures. An accessible cleanout shall be installed in the vertical portion of the foot vent.
(Reason: To clarify the installation of island venting and to provide a standard installation method for
the region. An air admittance valves installed according to section 3114 is an alternate venting
method to this section.)
Part VIII- Electrical, Chapters 33 through 42; Delete and add note as follows:
Note: Chapters 33 throuqh 42 are based on the 1999 National Electrical Code and are included here for
reference only. The National Electrical Code as adopted by separate ordinance takes precedence over these
sections
Section E3301. 1; add a sentence to read as follows:
All references to NFPA 70 shall mean the Electrical Code as adopted.
Appendix G; Change section AG105 as follows:
AG105.2 Outdoor swimming pool. An outdoor swimming pool, including an
In-ground, aboveground or on-ground pool, hot tub or spa shall be provided
with a barrier which shall comply with the following:
1. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the
side of the barrier which faces away from the swimming pool. The maximum vertical clearance
between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of
the barrier which faces away from the swimming pool. Where the top of the pool structure is above
grade, such as an aboveground pool, the barrier may be at ground level, such as the pool
structure, or mounted on top of the pool structure. Where the barrier is mounted on top of the pool
structure, the maximum vertical clearance between the top of the pool structure and the bottom of
the barrier shall be 4 inches (102 mm).
Pre-existina fences. The installation of a swimminq pool creates the requirement for the barrier
fence. A previously existinq fence would not have any status under this section because the
addition of the pool creates the hazard on which the code section is based. The one exception to
this qeneral rule is when the fence on one side of the new pool is already a pool enclosure for the
adjacent property. That fence seqment which is common to another yard with a pool is a leqal
nonconforminq pool enclosure and need not be upqraded. Any other existinq fence that is just now
becominq a pool enclosure shall comply with this section.
2. Openings in the barrier shall not allow passage of a 4-inch-diameter (102 mm) sphere.
3. Solid barriers which do not have openings, such as a masonry or stone wall, shall not contain
Indentations or protrusions except for normal construction tolerances and tooled masonry joints.
4. Where the barrier is composed of horizontal and vertical members and the distance between the
tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be
located on the swimming pool side of the fence. Spacing between vertical members shall not exceed
1.75 inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing
within the cutouts shall not exceed 1.75 inches (44 mm) in width.
5. Where the barrier is composed of horizontal and vertical members and the distance between the
tops of the horizontal members is 45 inches (1143 mm) or more, spacing between vertical members
shall not exceed 4 inches(1 02 mm). Where there are decorative cutouts within vertical members,
spacing within the cutouts shall not exceed 1.75 inches (44 mm) in width.
EXCEPTION: When horizontal members are part of a fence that is at least 6 feet (1830 mm) in
heiqht, the horizontal members need not be on the pool side of the barrier and the 45 inch distance
between horizontal members does not apply.
6. Maximum mesh size for chain link fences shall be a 2.25-inch (57 mm) square unless the fence is
provided with slats fastened at the top or the bottom which reduce the openings to not more than 1.75
nches (44 mm).
7. Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening
formed by the diagonal members shall not be more than 1.75 inches(44 mm).
8. Access gates shall comply with the requirements of Section AG105.2, Items 1 through 7, and shall
be equipped to accommodate a locking device. Pedestrian access gates shall open outward away
from the pool and shall be self-closing and have a self-latching device. Gates other than pedestrian
access shall h3'Je ;:¡ self 13tching devico be equipped with lockable hardware or padlocks and shall
remain locked at all times when not in use.
Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm)
from the bottom of the gate, the release mechanism and openings shall comply with the following:
8.1. The release mechanism shall be located on the pool side of the gate at least 3 inches (76
mm) below the top of the gate, and
8.2. The gate and barrier shall have no opening greater than 0.5 inch (12.7 mm) within 18 inches
(457 mm) of the release mechanism.
Vehicle qates desiqned or intended to be used on a reqular basis may be automatic closinq rather
than maintained locked. Automatic qates may be opened by a key or switch (fixed or remote) but the
qate shall automatically close within one to two minutes without requirinq any additional action on the
part of the person who opened it.
9 Where a wall of a dwelling serves as part of the barrier one of the following conditions shall be met:
91. The pool shall be equipped with a powered safety cover in compliance with ASTM F1346; or
9.2. All doors with direct access to the pool through that wall shall be equipped with an alarm
which produces an audible warning when the door and its screen, if present, are opened. The
alarm shall sound continuously for a minimum of 30 seconds immediately after the door is opened
and be capable of being heard throughout the house during normal household activities. The
alarm shall automatically reset under all conditions. The alarm system shall be equipped with a
manual means, such as touchpad or switch, to temporarily deactivate the alarm for a single
opening. Such deactivation shall last for not more than 15 seconds. The deactivation switch(es)
shall be located at least 54 inches (1372 mm) above the threshold of the door; or
9.3. Other means of protection, such as self-closing doors with self-latching devices, which are
approved by the governing body, shall be acceptable so long as the degree of protection afforded
IS not less than the protection afforded by Item 9.1 or 9.2 described above
10. Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top
of the pool structure, and the means of access is a ladder or steps, then:
10.1. The ladder or steps shall be capable of being secured, locked or removed to prevent access,
or
10.2. The ladder or steps shall be surrounded by a barrier which meets the requirements of
Section AG1 05.2, Items 1 through 9. When the ladder or steps are secured, locked or removed,
any opening created shall not allow the passage of a 4-inch-diameter (102 mm) sphere.
(Reason: To allow for special conditions while retaining essentially the same degree of safety.)
END OF AMENDMENTS.
INVOICE
Star-Telegram Customer ID: CIT57
400 W.7th Street Invoice Number: 243462991
FORT WORTH,TX 76102
(817)390-7761 Invoice Date: 7/6/04
Federal Tax ID 22-3148254 Terms: Net due in 21 days
•
Due Date: 7/31/04
Bill To: PO Number:
CITY OF SOUTHLAKE
1400 MAIN ST Order Number: 24346299
STE 440 Sales Rep: 073
SOUTHLAKE, TX 76092-7604 Description: CITY OF SOUTHLA
Publication Date: 7/6/04
dt: ... r Vi; a 8 € a : � 9 ,< -� ��_ ��_ �s-as 8 t7i ' A 1 '1".:. - a30 e € '�x. a A _ z , ,, � yw�,—srs,—
CITY OF SOUTHLAKE Notice is he 13580 1 113 113 LINE $0.81 $91.53
SOUTHLOAFKE Any person,
firm vio-
Notice Is hereby given lates,disobeys,omits.
by the City Council of neglects or refuses to $91.53
the City of Southlake, comply with or who Net Amount:
Texas, that a public resists the enforce-
has will be held ment of any of the.
Qri mr provisions of this or-
b• MMt4ij dinance shall be fined
tl», not more than Two
W Session, i Thousand Dollars ($
2,000.00) for all vio-
the Regular lations involving zon-
Council meeting ing, fire safety or
held in the public, health and
Council Cha sanitation, Including
Town Hall,1400
Street, Southla dumping or refuse
Texas.Purpose of fit and shall be fined un-
rP more than five for
public hearing is lb- dred dollars($500)for
consider the second. all other violations of
reading of the fol. this ordinance each.
lowing ordinance: day that a violation IS
2003 International permitted to exist shall
Residential Gp constitute a separate
ORDINANCE8 NO._ Myerpf�e�orl
4 L•46 FarwM eke ..
ADOPTINODINA,:,, gyy At
.
2003 EDIT• Secretary
CHRISTY L.HOLLANC
TAL HE INTER r ]LL•' '' MY COMMISSION EXFIFES
CODE RTj►.Fyj�pp�t_,F �• Yr. sirf.,,4::f4ik;—="7---------,.t-t4.,:).
„,.,. JULY 31,2004
THE STATE ULWAT NG 1
County of T. ERECTION CON-
STRUCTION EN-
LARGEMENt AL-
TERATION, RRI FEMOVAL;
Before me,2 DEMOLItION, Co _ Ir said County and State,this day personally appeared Lisa Wesselman, Bid and Legal Coordinator
for the Star- VERSION, OC CU- the Star-Telegram, Inc.at Fort Worth, in Tarrant County,Texas;and who, after being duly sworn, did depose and say
that the attar HEIGHT AREA a,Nd rtisement was published in the boy med paper on the lisle dates: BIDS 81 LEGAL DEPT. STAR TLEGRAM
(817) 390- ALL MAINONETEN-ANCEAND OF •
TWO-
FAMILY DWELLINGS
AND MULTIPLE
SINGLE-FAMILY Signed
DWELLINGS
( OWNHOUSES) IN
SUBSCRIBE TTSOUTHLAKE AND FORE ME, THIS Saturday,July 10,2
PROVIDING FOR
THE ADOPTION OF
LOCAL AMEND-
MENTS TING ER FTO- Notary Public fa I/
RECORDING OF
SUCH CODE AS A
PUBLIC RECORD
PROVIDING THAT
THIS ORDINANCE
Thank Yc SHALL BE OF
OF ALL yment
ORDINANCES;
PROVIDING A SEV-
ERABILITY CLAUSE;
PROVIDING FOR A
PENALTY FOR VIO-
LATIONS HEREOF;
PROVIDING A SAV-
PROVIDINCLAUSE,'
FOR
Remit Tc pPAMPHLETO FORM Customer ID: CIT57
PROVIDING FOFI
PUUg LIICATI it ►51 Customer Name: CITY OF SOUTHLAKE
PERCOTTV��(DEPDARfA H, TX 76101-2051 Invoice Number: 243462991
SECTION 6
Invoice Amount: $91.53
PO Number:
Amount Enclosed: ?$
INVOICE .-'
Star-Telegram Customer ID: CIT57
400 W. 7th Street Invoice Number: 244155791
FORT WORTH,TX 76102
(817)390-7761 Invoice Date: 7/23/04
Federal Tax ID 22-3148254 Terms: Net due in 21 days
Due Date: 7/31/04
Bill To: PO Number:
CITY OF SOUTHLAKE
1400 MAIN ST Order Number: 24415579
STE 440 Sales Rep: 073
SOUTHLAKE, TX 76092-7604 Description: CITY OF SOUTHLA
Publication Date: 7/23/04
I Description Location Col Depth Linage Mtn 'a P I i ` I =
CITY OF SOUTHLAKE 2003 Interna I358() 1 100 100 LINE $0.81 $81.00
CITY OF
SOUTHLAKE
2003 International
Residential Code
ORDINANCE
AN N ORDINANCE Net Amount: $81.00
ADOPTING THE
2003 EDITION OF
THE INTERNATION-
AL RESIDENTIAL
CODE FOR ONE-
AND TWO-FAMILY
DWELLINGS, REG-
ULATING THE -'
ERECTION CON-
STRUCTIONI EN- c j 1 j Vi k
LARGEMENT_, AL-
TERATION REPAIR,
MOVING REMOVAL,
DEMOLITION, CON-
VERSION, OCCU-
PANCY, EQUIP-
MENT, 5 L 4
MAINENANCE AND 2 AU6
ALL ONE-AND TWO-
FAMILY DWELLINGS
AND MULTIPLE
SINGLE-FAMILYD r------li.kr-;CN
CHRISTYL.HOLLANDOFFICE OF CITY SECRETARY
TOWNHOUSES) IN
( MYCOMMISSION EXPIRES
THECITYOFSOUTHLAKE AND , +�' JU 31,PROVIDING FORQ},� 7 2008
F
THE STAT LOCALDOPTAMEND-
County Of PROV DING THERETO_;
RECORDING OF
SUCH CODE AS A
Before me PUBLIC RECORD
r PROVIDING THAT or said County and State,this day personally appeared Lisa Wesselman, Bid and Legal Coordinator
for the Star SHALL BEDI CUMU the Star-Telegram, Inc.at Fort Worth, in T rrant County, Texas; and who,after being duly sworn, did depose and say
that the att; O RIDE N°N C E sL ertisement was published in the above nam aper on the listed dates: BIDS 81 LEGAL DEPT. STAR TLEGRAM
(817) 39( ERABILIIITNYGCLAUSE;
`
PROVIDING FOR A
PENALTY FOR VIO- ('t
PROVIDING ARSAV- Signed �J�� U..._5221/--• ,
PROVIDING LA FOE
SUBSCRIBE PUBLICA IONFORM EFORE ME, THIS Thursday,July 29, 2004.PROVIDING F INPUBLICATION INLA
THE OFFICIAL
NEWSPAPER; AND Notary Public
PROVIDING AN EF-
FECTIVE DATE.
SECTION 6
Any person, firm or
corporation who vio-
lates,disobeys,omits.
Thank Y( neglects or refuses to yment
comply with or who
resists fthe e nofo rceo oy this or-
poainso shall be fined
not more than Two
Thousand Dollars
(62,000.00) for all vi-
olations involving
Remit To zoning, fire safety or Customer ID: CIT57
public. health and
sanitation, including
dumping or refuse, 151 Customer Name: CITY OF SOUTHLAKE
and shall be fined not
more than five hun-
dred d dollars
olla o(lations of$500)for H, TX 76101-2051 Invoice Number: 24415 5791
this ordinance each
day that a violation is $81.00permitted to exist shall Invoice Amount:
constitute a separate
Popffgegn�sep. AND AP- PO Number:
PROVED THIS THE
21. DURING
DAY OF J THY
2 ((����D,�U, CITY
Amount Enclosed: $
C i iJL`IL MEETING.
M YOR: armsAndy
I AV�Lon Farwell, 1
• City Secretary