2003 International Plumbing Code
ORDINANCE NO. 873
OFFICIAL RECO~'~
AN ORDINANCE ADOPTING THE INTERNA TIONAL PLUMBING CODE, 2003 EDITION;
PROVIDING FOR THE ADOPTION OF LOCAL AMENDMENTS THERETO; PROVIDING FOR
RECORDING OF SUCH CODE AS A PUBLIC_RECORD; PROVIDING THAT THIS ORDINANCE
SHALL BE CUMlTLATIVE OF ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE;
PROVIDING A SAVINGS CLAUSE; PROVIDING FOR PUBLICATION IN PAMPHLET FORM;
PROVIDING FOR PlIBLICATlOl\' Il\' THE OFFICIAL l\'EWSPAPER; AND PROVIDING AN
EFFECTIVE DATE.
WHEREAS. The City of Southlake, Texas is a home rule city acting under its charter adopted by the electorate pursuant
to Article XI. Section" of the Texas Constitution and Chapter 9 of the Local Government Code; and
WHEREAS. City Council of the City of Southlake deems it necessary to adopt this ordinance governing requirements for
the insta11ation and maintenance of plumbing systems inc1uding requirements for materials, in order to protect the health,
safety and welfare of the citizens ofthe City of South lake,
WHEREAS, beginning in the summer of 2003, NCTCOG's Regional Codes Coordinating Committee (RCCC) and its
four advisory boards conducted 26 open review meetings over a lO-month period to review the 2003 editions of the
InternatIOnal Codes and to develop regional amendments, Their review and recommendations were completed and
endorsed by NCTCOG's Executive Board in March 2004, Now NCTCOG encourages jurisdictions in North Central
TL'xas to adopt the 2003 International Plumbing Code along with its respective regional amendments with an effective
date of .July L 2004,
NOW. THEREFORE, BE IT ORDAINED BY THE CITY COeNCIL OF THE CITY OF SOUTHLAKE,
TEXAS:
SECTION 1
That the 111lernational Plumbing Code, 2003 Edition. published by The International Code Council, Inc., is
hereby adopted as the Plumbing Code of the City of Southlake, except for plumbing systems otherwise
regulated under the International Residential Code for One- and Two- Family Dwellings as adopted. A true
and conect copy of this Code is attached to this ordinance as Exhibit" A."
SECTION 2
That the 2003 International Plumbing Code. as adopted herein, is hereby amended as provided in Exhibit
"B" incorporated herein and attached hereto for all purposes of this ordinance. The City of Southlake may
from 1¡me to time determine that additIOnal local modifications to the 2003 International Plumbing Code
are necessary and appropriate to meet the unique construction needs of the City of Southlake, To
effectuate these modifications, the City council shall enact individual ordinances amending this ordinance
full) setting forth the change to be made In the code. Upon adoption. copies of these amendments shall
be attached to ExhibIt "B" to thIs Ordinance,
SECTION 3
The material contained in Exhibits "A" and "B"_to this ordinance shall not be included in thejormal
mulllcipal codifìcation of ordinances, but shall be maintained as a public record in the offìce of the City
BuJidl11g omclal and will be available for public inspection and copying during regular business hours.
SECTION 4
ThIs ordinance shall be cumulative of all provisions of ordinances of the City of Southlake, Texas, except
where the provisions of this ordinance are in direct conflict with the provisions of such ordinances. in
whIch event the conflicting provisIons of such ordinances are hereby repealed.
SECTION 5
It IS hereby declared to be the intention of the City Council that the phrases, clauses, sentences,
paragraphs and sections of this ordinance are severable, and if any phrase, clause, sentence, paragraph or
section of this ordlllance shall be declared unconstitutional by the valid judgment or decree of any court
of competent junsdiction, such unconstitutionality shall not affect any of the remaining phrases, clauses,
sentences,paragraphs and sections of this ordinance, since the same would have been enacted by the City
council without the incorporation in this ordinance of any such unconstitutional phrase, clause, sentence,
paragraph or section. It is not the intention of this ordinance to conflict in any way with the Plumbing
License Law of Texas.
SECTION 6
Any person, firm or corporation who violates, disobeys, omits, neglects or refuses to comply with or who
resists the enforcement of any of the provisions of this ordinance shall be fined not more than Two
Thousand Dollars ($2,000.00) for all violations involving zoning, fire safety or public_health and
sanitation, including dumping or refuse, and shall be fined not more than five hundred dollars ($500) for
all other violations of this ordinance. Each day that a violation is permitted to exist shall constitute a
separate offense.
SECTION 7
All rights and remedies of the City of Southlake are expressly saved as to any and all violations of the
provisions of any ordinances affecting the installation and maintenance of systems which have accrued at
the time of the effective date of this ordinance; and, as to such accrued violations and all pending
litigation,both civil and criminal, whether pending in court or not, under such ordinances, same shall not
be affected by this ordinance buy may be prosecuted until final disposition by the courts.
SECTION 8
The City Secretary of the City of Southlake is hereby authorized to publish this ordinance in book or
pamphlet form for general distribution among the public, and the operative provisions of this ordinance as
so published shall be admissible in evidence in all courts without further proof than the production
thereof.
SECTION 9
The City Secretary of the City of Southlake is hereby directed to publish in the official newspaper of the
City of Southlake, the caption, penalty clause, publication clause and effective date_of this ordinance one
time within ten days after passage of this ordinance, as required by Section 3.13 of the Charter of the City
of Southlake.
SECTION 10
This ordinance shall be in full force and effect from and after its passage and publication as required by
law,but not sooner than September 30,2004 and it is so ordained.
Passed And Approved On First Reading On This 1301 Day Of la' , 2004.
MAYOROff,••• ,,,,,,
n = V•
•
ir
ATTEST: An
.•
CITY SECRETARY •
•••••••••••
2
Passed And Approved On Second Reading On This 20 h,Day Of jIth.4 , 2004.
MA R
.% tF
ATTEST: io.A.; 'U /` •
•
CITY SECRETARY '
APPRO D AS TO FORM)ND LEGALITY:
City Attorney
Date: R.A.DY
EFFECTIVE: 1-,93.DA
3
EXHIBIT "B"
Amendments to the
2003 International Plumbing Code
The following sections, paragraphs, and sentences of the 2003 International Plumbing Code are hereby amended as
follows:
(Standard type is text from the IPC Underlined type is text inserted. Lined through type is deleted text from 'PC,) After
each amendment a reason IS given in parentheses, The reason is not a part of the code, but is given to aid in
understanding of the code.
**Table of Contents, Chapter 7, Section 714; change to read as follows:
Section 714 Enqineered Computerized Drainage Design. . , .. . , . . ., ...62
(Reason: Editorial change to make compatible with amendment to Section 714.1,)
***Section 101.2; change exceptions 1 and 2 as follows:
101.2 Scope (Paragraph unchanged)
Exceptions:
1, Detached one and two- family dwellings. . . (unchanged) . . . International Residential
Code as adopted.
2, Plumbing systems in existing buildings, . . (unchanged) . . . International Existing
Building Code or the provisions for existinq buildinqs in the International Buildinq Code
as adopted.
(Reason: Recognize amendments to the IRC and IEBC alternates.)
**Section 102.8; change to read as follows:
102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are
listed In Chapter 13 and such codes, when specifically adopted, and standards shall be considered as part of the
requirements of this code to the prescribed extent of each such reference, Where the differences occur between
provisions of this code and the referenced standards, the provisions of this code shall be the minimum requirements.
Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and
standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the ICC Electrical
Code shall mean the Electrical Code as adopted,
(Reason: Legal wording to recognize locally adopted codes and amendments adopted with referenced codes.)
***Sections 106.6.2 and 106.6.3; change to read as follows:
106.6.2 Fee schedule. The fees for all plumbing work shall be as indic3ted in the folloY.ling
schedule: (JURISDICTION TO INSERT ^PPROPRIATE SCHEDULE) adopted by resolution of the
city council.
106.6.3 Fee Refunds. The code official shall establish a policy for 3uthorizo authorizinq the
refunding of fees. 3S follows. (Oelete balance of section)
(Reason: This calls to attention the fee schedule and refund policy.)
***Section 109; Delete entire section and insert the following:
SECTION 109
MEANS OF APPEAL
109.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the buildinq official
relative to the application and interpretation of this code, there shall be and is hereby created a board of appeals. The
4
Buildinq Board of Appeals as established by ordinance 622 as amended shall constitute the Board of Appeals
referenced in this code,
109.2 Limitations on authority. An application for appeal shall be based on a claim that the true intent of this code or
the rules leqally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or
an equally qood or better form of construction is proposed, The board shall have no authority to waive requirements of
this code,
(Reason: recognize appeal board previously established by ordinance,)
**Section 305.6.1; change to read as follows:
305.6.1 Sewer depth. Building sowors th3t connoct to priv3te se'o'/3go dispOS31 systems sh311 be 3 minimum of
[numbor] inches (mm) below finished gr3de at the point of septic t3nk connection, Building sewers shall be a minimum
of J1. Inches (304 mm) below grade.
(Reason: Provides sewer depth that is common in this region, Deleted reference to private sewage disposal because
a private sewage disposal code is not adopted.)
**Section 305.9; change to read as follows:
305.9 Protection of components of plumbing system. Components of a plumbing system installed within 3 feet
along alleyways, driveways, parking garages or other locations in a manner in which they would be exposed to
damage shall be recessed into the wall or otherwise protected in an approved manner.
(Reason: Provide a common cutoff point to designate a general separation distance at which plumbing systems
should be safe for consistency in enforcement)
**Section 310.4; delete.
(Reason: Enforcement of privacy walls and doors, and the maintenance thereof, should not be a code issue. It is an
owner courtesy issue,)
**Sections 312.9.1 and 312.9.2; change to read as follows:
312.9.1 Inspections. Annual inspections shall be made of all backflow prevention assemblies and air gaps to
determine whether they are operable. (See Ordinance No. 699, Cross Connection Control Policy.)
312.9.2 Testing. Reduced pressure principle backflow preventer assemblies, double check-valve assemblies,
pressure vacuum breaker assemblies, reduced pressure detector fire protection backflow prevention assemblies,
double check detector fire protection backflow prevention assemblies, hose connection backflow preventers, and spill-
proof vacuum breakers shall be tested at the time of installation, immediately after repairs or relocation and at least
annually, The testing procedure shall be performed in accordance with applicable local provisions. In the absence of
local provisions, the owner IS responsible to ensure that testinq is done in accordance with one of the following
standards:
{list of standards unchanged}
(Reason: Recognize TCEQ or other local testing procedures that must be adhered to, To place responsibility of
testing on the owner.)
**Section 314.2.1; modify second sentence to read as follows:
314.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain
pan outlet to an approved place of disposal, Condensate shall not discharge into a street, alley, sidewalk, rooftop, or
other areas so as to cause a nuisance,
(Reasor)'. Greater specificity in prohibited locations for condensate discharge, Consistent with regional amendment to
IMC 3072,1)
***Section 314.2.2; change to read as follows:
314.2.2 Drain pipe materials and sizes. Components of the condensate disposal system shall
be cast iron, galvanized steel, copper, cross-linked polyethylene, polybutylene, polyethylene, ABS,
CPVC or PVC pipe or tubing. All components shall be selected for the pressureLaOO temperature~
5
and exposure rating of the installation. {Remainder unchanged}
(Reason: To require UV protection.)
**Section 401.1; add a sentence to read as follows:
The provisions of this Chapter are intended to work in coordination with the provisions of the Buildinq Code, Should
any conflicts arise between the two chapters, the Code Official shall determine which provision applies.
(Reason: Gives discretion to Code Official in case of code conflict.)
**Section 403.1; change to read as follows:
403.1 Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the
minimum number as follows:
1. Assembly Occupancies: At least one drinkinq fountain shall be provided at each floor level in an approved
location,
Exception: A drinkinq fountain need not be provided in a drinkinq or dininq establishment.
2. Groups A. B, F, H, I, M and S Occupancies: Buildinqs or portions thereof where persons are employed shall
be provided with at least one water closet for each sex except as provided for in Section 403,2.
3, Group E Occupancies: Shall be provided with fixtures as shown in Table 403.1.
4, Group R Occupancies: Shall be provided with fixtures as shown in Table 403.1,
It is recommended, but not required, that the minimum number of fixtures provided also comply with the number shown
in Table 403.1 Types of occupancies not shown in Table 403.1 shall be considered individually by the code official,
The number of occupants shall be determined by the International Building Code, Occupancy classification shall be
determined in accordance with the International Building Code,
**Add Section 403.1.2 to read as follows:
403.1.2 Finish material. Finish materials shall comply with Section 1209 of the International BuildinG Code.
(Reason: Table 403.1 is made optional, Gives minimum requirements in body of code. Consistent with regional
amendments to IBC Section 2902,)
**Section 405.6; delete.
(Reason: Texas State regulations cover plumbing in mental health centers, Consistent with regional amendment to
¡PC 100210.)
**Section 409.2; change to read as follows:
409.2 Water connection. The water supply to a commercial dishwashing machine shall be protected against
backflow by an air gap or backflow preventer in accordance with Section 608.
(Reason: Domestic dishwashing machines would be difficult to enforce and should already come equipped with
backflow preventers. Consistent with regional amendments in IPC Section 608.)
**Section 410.1; change to read as follows:
410.1 Approval. Drinking fountains shall conform to ASME A112.19.1 M, ASME A112.19.2M or ASME A112.19,9M,
and water coolers shall conform to ARI 1010, Drinking fountains and water coolers shall conform to NSF 61, Section
9. Where 'tKJter is served in rostaur3nts or whew bottled 't/3ter coolers 3m providod in othor occup3ncies, drinking
fountJins shall not be required. In other occupancies, where drinking fountains 3re roquired, bottled w3tor dicpem:.ors
shall be permitted to be substituted for not more th3n 50 percent of the required drinking fount3ins,
Exception: A drinkinq fountain need not be provided in a drinkinq or dininq establishment.
(Reason: Coincide with amendments made to ¡PC 403.1 and IBC 2902,1,)
**Section 412.4; change to read as follows:
6
412.4 Required location Public laundries and central washing facilities. Floor drains shall be installed in the
followlnq areas,
1- In public coin-operated laundries and in the central washing facilities of multiple family dwellings, the rooms
containing automatic clothes washers shall be provided with floor drains located to readily drain the entire floor
area, Such drains sh311 h3'.'e :3 minimum outlot of not loss th:3n 3 inches (76 mm) in di3motor.
~ Nonresidential kitchens. (In lieu of floor drains in nonresidential kitchens, the code official may accept floor
sinks)
(Reason: To make more compatible with local health code practices.)
**Section 413.4; change to read as follows:
413.4 Water supply required. All food waste grinders shall be provided with a supply of cold water. The water
supply shall be protected aqainst backflow by an air qap or with the installation of a backflow preventer in accordance
with Section 608,
(Reason: Consistent with local practice and regulations. Consistent with regional amendments in ¡PC Section 608.)
**Section 417.5; change to read as follows:
417.5 Shower floors or receptors. Floor surfaces shall be constructed of impervious, noncorrosive, nonabsorbent
and waterproof materials,
Thresholds shall be a minimum of 2 inches (51 mm) and a maximum of 9 inches (229 mm), measured from top of the
drain to top of threshold or dam. Thresholds shall be of sufficient width to accommodate a minimum twenty-two (22)
inch (559 mm) door,
Exception: Showers desiqned to comply with ICC/ANSI A117, 1,
(Reason: To provide more specific requirements,)
**Section 417.5.2; change to read as follows:
417.5.2 Shower lining. Floors under shower compartments, except where prefabricated receptors have been
provided, shall be lined and made water tight utilizing material complying with Sections 417.52.1 through 417.5,2.4,
Such liners shall turn up on all sides at least 2 ~ inches (M 76 mm) above the finished threshold level and shall extend
outward over the threshold and fastened to the outside of the threshold jamb. Liners shall be recessed and fastened
to an approved backing. . , {remainder of section unchanged} . , . .
(Reason: Consistent with local practice.)
**Add Section 417.7 to read as follows:
417.7 Test for shower receptors. Shower receptors shall be tested for water tiqhtness by fillinq with water to the
level of the rouqh threshold. The drain shall be pluqqed in a manner so that both sides of pans shall be subjected to
the test at the point where it is clamped to the drain.
(Reason To clarify that a water test is required for a shower receptor.)
**Section 419.3; change to read as follows:
419.3 Surrounding material. Wall and floor space to a point 2 feet (610 mm) in front of a urinal lip and 4 feet (1219
mm) above the floor and at least 2 feet (610 mm) to each side of the urinal shall be waterproofed with a smooth,
readily cleanable, hard, nonabsorbent material
(Reason: Match unamended IBC 1209,)
**Section 502.3; change to read as follows:
502.3 Water heaters installed in attics. Attics containing a water heater shall be provided. . . {bulk of paragraph
unchanged} .. side of the water heater. The clear access opening dimensions shall be a minimum of 20 inches by 30
Inches (508 mm by 762 mm), or larqer where such dimensions are not large enough to allow removal of the water
heater
(Reason To ensure adequate access,)
7
**Add Section 502.5 to read as follows:
502.5 Water heaters above Qround or floor. When the attic, roof, mezzanine or platform in which a water heater is
installed is more than eiqht (8) feet (2438 mm) above the qround or floor level, it shall be made accessible by a
stairway or permanent ladder fastened to the buildinq.
502.5.1 Whenever the mezzanine or platform is not adequately liqhted or access to a receptacle outlet from
the main level is not obtainable, liqhtinq and a receptacle outlet shall be provided in accordance with Section
50231,
(Reason: To provide safe access to water heaters and to provide lighting and receptacle for maintenance of
equipment Consistent with regional amendments to IFGC 306,1 and IMC 306.7. Note reference to amendment
above)
**Section 504.6.1; change to read as follows:
504.6.1 Discharge. The relief valve shall discharge throuqh full size QlQlQg to a safe place of disposal such as 9. tAB
floor drain, outside the building, or an indirect waste receptor, The discharge pipe shall not have any trapped sections~
When the drain pipe run is exposed in an area outside of the room where the water heater is located, in a manner that
would make it subject to damaqe, the drain aM shall have a visible air gap or air gap fitting located in the same room
as the water heater. The outlet end of the discharge pipe shall not be threaded and such discharge pipe shall not have
a valve or tee installed, Relief valve piping shall be piped independent of other equipment drains or relief valve
discharge piping to the disposal point Such pipe shall be installed in a manner that does not cause personal injury to
occupants in the immediate area or structural damage to the building. The discharqe pipe shall not discharqe into the
pan required in Section 504,7.
When discharqinq outside the buildinq, the point of discharqe shall be with the end of the pipe not more than
two (2) feet (610 mm) nor less than six (6) inches (152 mm) above the qround or the floor level of the area receivinq
the discharqe and pointinq downward, (Reason: To provide a higher degree of safety.)
**Add Section 604.4.1 to read as follows:
604.4.1 State maximum flow rate. Where the State mandated maximum flow rate is more restrictive than those of
this section, the State flow rate shall take precedence,
(Reason: To recognize State standards.)
**Tables 605.3 and 605.4; delete "Polybutylene (PB) plastic pipe and tubing".
(Reason: Polybutylene pipe is not allowed for use in this region,)
**Section 606.1; delete items #4 and #5.
606.1 Location of full-open valves. Full-open valves shall be installed in the following locations:
1. On the building water service pipe from the public water supply near the curb.
2 On the water distribution supply pipe at the entrance into the structure,
3 On the discharge side of every water meter,
4c On the b3£O of overy w3ter riser pipe in occupancies other than multiple family residential occupancies that
3re two stories or less in height and in one and two family residenti31 occup3ncios.
5. On the top of ovary 'N3tor do'.",," food pipe in occup3ncios other than one and two family residential
occupancies,
6 On the entrance to every water supply pipe to a dwelling unit, except where supplying a single fixture
equipped with individual stops.
7 On t~e water supply pipe to a gravity or pressurized water tank,
8. On the water supply pipe to every water heater.
(Reason: The code is too restrictive as written.)
**Section 606.2; items #1 and 2 change to read as follows:
On the fixture supply to each plumbing fixture~ other than b3thtubs and showers in one and tW? f3mily residential
occup3ncios, and other than in individual guostrooms that aro provided with unit shutoff v31ves In hotels, motels,
b03rding houses and simil3r occupancies.
8
Exception: Tub and shower valves,
2 On the water supply pipe to each sillcock when subject to freezinq,
(Reason: To provide shut-off valves to every fixture,)
**Section 608.1; change to read as follows:
608.1 General. A potable water supply system shall be designed, installed and maintained in such a manner so as to
prevent contamination from non potable liquids, solids or gases being introduced into the potable water supply through
cross-connections or any other piping connections to the system, Backflow preventer applications shall conform to
applicable local requlations (See Cross Connection Control Policy Ordinance No, 699), Table 608,1, ~ and as
specifically stated in Sections 608,2 through 608,16,9.
(Reason: To recognize local requirements,)
***Section 608.16.5; change to read as follows:
608.16.5 Connections to lawn Irrigation Systems. The potable water supply system to lawn
irrigation systems shall be protected G.y against backflow by an atmospheric-type vacuum breaker,
a pressure type vacuum breaker, a double-check assembly or a reduced pressure principle
backflow preventer . . . {remainder of section unchanged}.
(Reason: To recognize regional practices,)
**Section 608.17; change to read as follows:
608.17 Protection of individual water supplies. An individual water supply shall be located and constructed so as to
be safeguarded against contamination in accordance with applicable local requlations. In the absence of other local
requlations, installation shall be in accordance with Sections 608,17.1 through 608.17,8.
(Reason: To allow local requirements to govern)
**Add Section 712.5 to read as follows:
712.5 Dual Pump System. All sumps shall be automatically discharqed and, when in any "public use" occupancy
where the sump serves more than 10 fixture units, shall be provided with dual pumps or ejectors arranqed to function
independently in case of overload or mechanical failure, For storm drainaqe sumps and pumpinq systems, see
Section 1113,
(Reason: To address dual pump system, To provide reference for storm drainage systems,)
**Section 714, 714.1; change to read as follows:
SECTION 714
ENGINEERED COMPUTERIZED DRAINAGE DESIGN
714.1 Design of drainage system. The sizing, design and layout of the drainage system shall be permitted to be
designed by approved computor design methods.
(Reason: Code was too restrictive,)
**Section 802.4; add a sentence to read as follows:
No standpipe shall be installed below the qround.
(Reason: To make systems less susceptible to improper modifications.)
**Section 904.1; changed to read as follows:
904.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least six (6) inches (152
mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent
extensions shall be run at least 7 feet (2134 mm) above the roof.
9
(Reason: To provide regional guideline on standard installation method for this area,)
**Section 912.1; change to read as follows:
912.1 Type of fixture. A combination drain and vent system shall not serve fixtures other than floor drains, sff::Iks-,
lavatories, and drinking fountains standpipes, and indirect waste receptors, Combination drain and vent systems shall
not receive the discharge from a food waste grinder or clinical sink.
(Reason: To prevent trap siphoning of sinks and lavatories,)
**Section 912.2; change to read as follows:
912.2 Installation. The only vertical pipe of a combination drain and vent system shall be the connection between the
fixture drain of a sink, lavatory or drinking fountain standpipe, and the horizontal combination drain and vent pipe, The
maximum vertical distance shall be 8 feet (2438 mm).
(Reason: To prevent trap siphoning of sinks and lavatories,)
**Section 1002.10; delete.
(Reason: Texas State regulations cover plumbing in mental health centers, Consistent with regional amendment to
IPC 405.6)
**Section 1106.1; change to read as follows:
1106.1 General. The size of the vertical conductors and leaders, building storm drains, building storm sewers, and
any horizontal branches of such drains or sewers shall be based on six (6) inches per hour the 100 ye3r hourly rainfall
rate indic3ted In Figure 1106.1 or on other rainfall rates determined from approved local weather data.
(Reason: Specify the roof drain size normally used in the area.)
**Section 1107.3; change to read as follows:
1107.3 Sizing of secondary drains. Secondary (emergency) roof drain systems shall be sized in accordance with
Section 1106 b3sed on the rainfall rate for which the primary system is sized in Tables 1106,2, 1106.3 3nd 1106,6.
Scuppers shall be sized to prevent the depth of ponding water. , , {remainder of section unchanged} , . . ,
(Reason: Specify that overflow drainage is to be the same size as the normal roof drains.)
***Section 1202.1; delete Exception 2.
(Reason: State law already specifies that vacuum systems must comply with NFPA 99C.)
END OF AMENDMENTS
10
INVOICE j', as
Star-Telegram Customer ID: CIT57
400 W.7th Street Invoice Number: 243462981
FORT WORTH,TX 76102
(817)390-7761 Invoice Date: 7/6/04
Federal Tax ID 22-3148254 Terms: Net due in 21 days
Due Date: 7/31/04
Bill To: PO Number:
CITY OF SOUTHLAKE
1400 MAIN ST Order Number: 24346298
STE 440 Sales Rep: 073
SOUTHLAKE, TX 76092-7604 Description: CITY OF SOUTHLA
Publication Date: 7/6/04
d k f b , 1,, » a $ ,;'es . } 3c At t.4 t,,
a
CITY OF SOUTHLAKE Notice is he 13580 1 87 87 LINE $0.81 $70.47
CITY OF
SOUTHLAKE
Notice is hereby given
by�rye c Council of $70.47
thetCity gat
Net Amount:
Texas,,g will that a public
on heJuly20, 2004,e t
6:00 p.m. or immedi-
ately following the
Work Session, during
the Regular City
Council meeting to be I
held in the City t
Council Chambers of -
Town Hall,1400 Main
Street, Southlake,
Texas.Purpose of the
public hearing is to
consider the second
reading of the fol-
lowin3gg ordinance:
20International03
ORDINA873E NO.
AN ORDINANCE CHRISTY L.,HOLLAND
ADOPTING THE IN- (;...1i6;TER NATIONAL
PLUMBING CODE '� MY COMMISSION EXPIRES
2003 EDITION !
PROVIDING FOR
THE ADOPTION OF ,. JULY 31,2004
THE STATE LOCAL AMEND-
MENTS THERETO•
PROVIDING FOFI
County of Ta RECORDINGE AS OF
SUCH COD A
PUBLIC RECORD,.
PROVIDING THAT
Before me,a THIS ORDINANCE
CUMUE said County and State,this day personally appeared Lisa Wesselman, Bid and Legal Coordinator
for the Star-T LATIVE OF ALL e Star-Telegram, Inc.at Fort Worth, in Tarrant County,Texas; and who, after being duly sworn, did depose and say
ORDINANCES that the attach PROVIDING A SEV isement was published in the above name paper on the listed dates: BI S ez LEGAL DEPT. STAR TLEGRAM
(817) 390-7 PROVIDING CLAUSE;- •
INGS FI
CLAUSE- ��
I PROVIDING FO
PUBLICATION IN
PAMPHLET FORM- Signed
PROVIDING FOFI
PUBLICATION IN
SUBSCRIBED 1 THE OFFICAL y,July 10,200 . s
NEWSPAPER AND�REI ME, THIS Saturday,
PROVIDING AN EF-
FECTIVE ' `l //C ('`JCTIO
Any person, firm or Notary Public
corporation who
omi s,
neglects or refuses to
comply with or who
resists the enforce-
ment of any of the
Thank You provisions o this or-rent
dinance shall be fined
not more than Two
Thousand Dollars
ogg2 000.00) for all,vi-
lafions involving
zoning, fire safety or
public health and
sanitation, including
dumping or refuse
t and shall be fined riot Customer ID: CIT57
Remit To: ` more than five hun-
dred dollars($500)for
1 amlis vioatioEeeh Customer Name: CITY OF SOUTHLAKE
day at a I at e`a ssepparate TX 76101-2051 Invoice Number: 243462981
offense.
City of Southiaks
LonFarwell Invoice Amount: $70.47
City Secretary
PO Number:
Amount Enclosed: ;$
INVOICE
Star-Telegram Customer ID: CIT57
400 W. 7th Street Invoice Number: 244155781
FORT WORTH,TX 76102
(817)390-7761 Invoice Date: 7/23/04
Federal Tax ID 22-3148254 Terms: Net due in 21 days
Due Date: 7/31/04
Bill To: PO Number:
CITY OF SOUTHLAKE
1400 MAIN ST Order Number: 24415578
STE 440 Sales Rep: 073
SOUTHLAKE, TX 76092-7604 Description: CITY OF SOUTHLA
Publication Date: 7/23/04
a�� 44 c , " I Q
v . z t,l1 ITS
CITY OF SOUTHLAKE 2003 Interna I3580 I 74 74 LINE $0.81 $59.94
CISOVTHLOEAKE
'2003I matiortai
'l•,:.NNal° Net Amount: $59.94
�dF� NANCE
ADOPTI HE IN-
TERNATIONAL
PLUMBING CODE,
2003 EDITION,
PROVIDING FOR
OEALDOP AMEND
j MENTS THERETO' \Y 1
i PROVIDING FOFt Iiiiilli 1 N1,
RECORDING OF
SUCH CODE AS A
PUBLIC RECORD:,
j•J6 5 2004
SHALL BE CUMU- PS
LATIVE OF ALL
ORDINANCES; ,
PROVIDING A SEV-
ERABILITY CLAUSE,
PROVIDING A SAV-
INGS CLAUSE_, OFFICE OF CITY SECRETARY
PROVIDING FOR
."T P'''
PUBLICATION IN t
PAMPHLET FORM_; :e? t; CHRISTY L.HOLLAND
PROVIDING FOR ;*: *= MY COMMISSION EXPIRES
PUBLICATION IN • ;la T, July 31,2U08
•
NEWSPAP OFFICIAL A "„Qr•"
THE STATE PROVIDING AN EF-
County of T FECSECTION 6.
Any person, firm or
corporation who vio-
Before me, later,disobeys,omds,ar said County and State, this
neglects or refuses to day personally appeared Lisa Wesselman, Bid and Legal Coordinator
for the Star- es S sv tneh e rfo ce°the Star-Telegram, Inc. at Fort Worth, in Tarrant County,Texas;and who, after being duly sworn, did depose and say
that the attar ment of any of the.rtisement was published in the above nam•paper on the listed d tes. BIDS 81 LEGAL DEPT. STAR TLEGRAM
provisions of this or
(81 7) 390 dinance shall be fined
not more than Two 1 k
Thousand Dollars
(42,000.00) for allvr Signed
z rings invety or 4
zoning, fire safety or
public health and
SUBSCRIBE[ dumpinogn'orinrefuse FORE ME, THIS Thursday,July 29, . i
and shall be fined not . j/ V
a-Ard
ic/4iimorethanfivehun- �
dred dollars S$500)for Notary Public
all other violations of
this ordinance. Each
day that a violation is
permitted to exist shall
constitute a separate
offense.
Thank Yo P ROVEQ TpHIS THE
.4 D Y1RING pTHE ment
rry
C r°OCIL MEETIp�,•
MAYOR:Y errs nay
ACHE Secretary
mall.
Remit To: Star-Telegram Customer ID: CIT57
P.O. Box 901051 Customer Name: CITY OF SOUTHLAKE
FORT WORTH, TX 76101-2051 Invoice Number: 244155781
Invoice Amount: $59.94
PO Number:
Amount Enclosed: $ -T 1